IDC 2XX with Cold Carbonation Installation Manual
Publication Number: 621057403INS
- 6 -
© 2005-2019, Cornelius Inc.
G
ATE
R
ESTRICTOR
P
LATE
AND
A
DJUSTMENT
The rate at which ice is dispensed can be adjusted by varying the opening of the gate restrictor plate as illustrated in
Figure 1. Reducing the dispense rate of ice is especially desirable when using glasses or other containers with small
openings. To adjust the gate restrictor plate, loosen the (4) nuts that hold the ice chute assembly to the bin. The
restrictor plate can now be moved up or down. When the restrictor plate is fully up, the ice gate opening is 2-1/2” in
height, and the maximum rate of ice dispense is available (approximately 3 oz/sec). Retighten the (4) nuts to set the
desired restrictor plate opening. DO NOT EXCEED 50 IN-LB of torque.
ADJUSTMENT
INSTALL PLATE
ON STUDS AS
SHOWN
4X
MAX TORQUE
50 in.-lb.
DISCONNECT POWER BEFORE INSTALLING,
REMOVING, OR ADJUSTING RESTRICTOR.
!
Figure 1. Gate Restrictor Plate
NOTE: Tighten (4) nuts for fastening lower ice chute in place to 50 in-lbs (max). Draw all four nuts tight
uniformly.