IDC 2XX with Cold Carbonation Installation Manual
Publication Number: 621057403INS
- 20 -
© 2005-2019, Cornelius Inc.
Contact your local syrup or beverage equipment distributor for additional information and troubleshooting of beverage
system.
Power cord is con-
nected but carbonator
pump does not run.
Carbonator pump motor is disabled.
Check the enable/disable switch on the car-
bonator pump terminal box and enable it, if
necessary.
Probes were dry, unit was powered up, water
was not turned on, and carbonator did not fill.
This results in a 5 minute timeout. Unplugging
the unit and plugging it in will reset the unit and
start the carbonator pump.
Water service was interrupted for more than 5
minutes.
Unplugging the unit and plugging it in will reset
the unit and start the carbonator pump.
Carbonator pump is
short cycling with every
drink drawn
Lower liquid level probe reads “dry” while
upper probe reads “wet”
Check color of leads going to probes. Black
should go to bottom probe and white to top
probe. Reverse if incorrect.
Carbonator tank over-
fills, overflows through
relief valve, and pump
shuts off after 5 minutes.
Poor electrical connections between carbon-
ator tank and main control board
Check connections at carbonator tank and at
connector J4 on the main control board.
Broken wires between carbonator tank and
main control board
Replace wire harness
Defective liquid level probes
Replace both liquid level probes