7
7. Fill the water pan with clean fresh water, circulate for approximately 3 minutes. Depress the DUMP
switch and allow the water to drain away. Repeat this procedure 3 times.
8. After third rinse cycle, place product power switch in ice position. Allow product to produce one slab
of ice – DISCARD THE ICE.
9. When clean cycle is complete, return cuber to normal operating mode.
NOTE:
Please Take Note of the Following:
S
Ice machines should only be cleaned when needed, not by a timed schedule of every 60
days, etc.
S
Should your ice machine require cleaning more than twice a year, consult your distribu-
tor or dealer about proper water treatment.
POWER SWITCH
SANITIZING PROCEDURES
NOTE:
To be performed only after cleaning the ice machine:
1. Add 1/4 ounce (7.08 g) sodium hypochlorite solution (common liquid laundry bleach) to the water
pan and allow the pump to circulate the solution for 5 minutes. You may also use a commercial sani-
tizer such as Calgon Ice Machine Sanitizer following the directions on the product label.
2. Turn the product power switch off and depress the dump switch to drain the water pan.
3. To sanitize the bin and other surface areas, use 1 ounce of liquid bleach per gallon of water and wipe
all areas with the solution. Or use a commercial sanitizer.
4. Place the product power switch in the ice position. Discard the first batch of ice produced.
5. Cleaning and sanitizing are now complete. Product may be returned to normal service.
OPERATING WATER LEVEL
227 UNITS
WATER PAN
RIGHT SIDE VIEW
ÎÎÎÎ