FREIGHT DAMAGE CLAIMS PROCEDURE

The deliverer of your equipment (freight company, distributor or dealer) is responsible for loss or damage
of your shipment. All claims must be filed with the deliverer of your equipment. Please follow the steps
below to determine if your shipment is satisfactory or if a claim must be filed:

1. Check the number of products delivered against the number of products listed on the delivery re-

ceipt. Should the totals not match, have the driver note all errors on both copies and both you and
the driver sign and date said notation.

2. Inspect all cartons for visible damage. Open and inspect as required before the driver leaves and

have him or her note any damage on the receipts. All damaged claims must be inspected within 15
days of delivery. Notify your carrier immediately if concealed damage is found after delivery.

3. Should concealed damage be found when product is unpacked, retain the packing material and the

product and request an inspection from the deliverer.

4. All claims for loss or damage should be filed at once. Delays in filing will reduce the chance of

achieving a satisfactory resolution to the claim.

SPECIFICATIONS, ICE CUBER

The following table contains equipment specification information for the Ice Cubers.

Model

IACS227

IWCS227

IACS227E60

IWCS227E60

IACS227E50

IWCS227E50

UNIT

Volts

115

230

220

Phase

1

Hertz

60

50

No. Wires

2+Ground

MIN. CIRCUIT
Amps

20

15

MAX. FUSE SIZE

Amps

20

15

REFRIGERANT

Type

R404A

Weight (oz)

17

15

17

15

17

15

Weight (g)

482

425

482

425

482

425

COMPRESSOR

Volts

115

230

220

Phase

1

Hertz

60

50

LRA

51

24

26

RLA

11.5

5.7

5.3

CONDENSER FAN MOTOR

Volts

115

230

220

Phase

1

Hertz

60

50

Amps

1.7

NA

1.2

NA

0.75

NA

Watts

50

NA

60

NA

50

NA

WATER PUMP

Volts

115

230

220

Phase

1

Hertz

60

50

Amps

0.88

0.5

Watts

1/40

1/30

Important: 

All product supply voltage specifications are –5%/+10% for proper component operation.

Содержание "I" Series 227

Страница 1: ... INSTRUCTIONS THIS DOCUMENT CONTAINS IMPORTANT INFORMATION This Manual must be read and understood before installing or operating this equipment Part No 630460042INS Release Date October 27 2003 Revision Date May 06 2014 Revision C CORNELIUS INC 2003 2014 PRINTED IN U S A ...

Страница 2: ...TRUCTIONS 2 LOCATION OF EQUIPMENT 2 PLUMBING CONNECTIONS 2 ELECTRICAL 4 INSTALLATION CHECK POINTS 4 START UP AND CHECK OUT 5 OWNER OPERATOR 6 CLEANING PROCEDURES 6 PREP CLEANING 6 CLEANING THE WATER SYSTEM EVAPORATOR 6 SANITIZING PROCEDURES 7 DUMP CYCLE 8 ADJUSTING BRIDGE THICKNESS 10 TOTAL ICE CAPACITY 10 ...

Страница 3: ...after delivery 3 Should concealed damage be found when product is unpacked retain the packing material and the product and request an inspection from the deliverer 4 All claims for loss or damage should be filed at once Delays in filing will reduce the chance of achieving a satisfactory resolution to the claim SPECIFICATIONS ICE CUBER The following table contains equipment specification informatio...

Страница 4: ...tion of your product ever be exposed to freezing temperatures it must be shut down and winterized FIGURE 1 INSTALLATION PLUMBING CONNECTIONS 1 All plumbing lines and connections must conform to local and national plumbing codes 2 Line shut off valves must be located in supply water lines for cuber and condenser if product is wa ter cooled Water supply to water cooled condenser must include a stand...

Страница 5: ...0 5 Á Á Á 2 06 IWCS 227 REAR VIEW Á Á 8 75 Á Á Á 2 25 1 ELECTRICAL CORD ATTACHED 20 AMP CIRCUIT 2 3 4 DRAIN TUBING SIZE 5 8 I D 3 3 8 RESERVOIR WATER INLET SAE MALE FLARE 4 3 4 BIN DRAIN STD PIPE SAE 5 5 8 CONDENSER WATER OUTLET MALE FLARE 6 5 8 CONDENSER WATER INLET MALE FLARE 1 ELECTRICAL CORD ATTACHED 20 AMP CIRCUIT 2 3 4 DRAIN TUBING SIZE 5 8 I D 3 3 8 WATER INLET SEA MALE FLARE 4 3 4 BIN DRAI...

Страница 6: ...and sanitized 2 Does electrical and plumbing meet code requirements 3 Check correct operating water level in the water pan OPERATING WATER LEVEL SINGLE EVAPORATOR WATER PAN RIGHT SIDE VIEW ÎÎÎÎ ÎÎÎÎ ÎÎÎÎ ÎÎÎÎ ÎÎÎÎ 2 38 FIGURE 3 SINGLE EVAPORATOR WATER LEVEL 4 If water cooled are inlet and drain connections to condenser correct to prevent water hammer 5 Are drain lines separate and vented 6 Is ther...

Страница 7: ...ill operate when the evaporator cools to 25_F 3 9_C De press the manual harvest switch located on the circuit board The fan motor will stop and the water dump valve will open In 3 seconds the hot gas solenoid will open and 15 seconds after depressing the manual harvest switch the water pump will stop and the dump valve will close terminating the dump cycle 3 Hold the water curtain open for a maxim...

Страница 8: ...When using any chemical rubber gloves and eye protection should be worn PREP CLEANING Use full strength ice machine cleaner on a coarse surface cloth material such as terry cloth and wipe down the inside wall of the evaporator area the water pan the water curtain and evaporator plastic extru sions If the water distributor tube has heavy scale build up remove and soak it in full strength ice ma chi...

Страница 9: ...CEDURES NOTE To be performed only after cleaning the ice machine 1 Add 1 4 ounce 7 08 g sodium hypochlorite solution common liquid laundry bleach to the water pan and allow the pump to circulate the solution for 5 minutes You may also use a commercial sani tizer such as Calgon Ice Machine Sanitizer following the directions on the product label 2 Turn the product power switch off and depress the du...

Страница 10: ...h cycle S every 7th cycle Remember the higher the mineral content in the water supply the more often it will be required to dump the water and or clean the product if proper water treatment is not used Transformer RD Error OFF OFF OFF ON ON ON SW4 SW4 SW4 5 6 YL YL YL YL S3 1 S3 2 OFF ON GR Comp Micro Processor 4 Curtain Switch Connected To Any Bin Connector J4 J7 FACTORY SETTING AS RECEIVED Sucti...

Страница 11: ...9 ...

Страница 12: ...ocated on the circuit board as follows 1 Thinner Bridge turn the ice thickness pot adjustment screw CW one full turn Allow two cycles before determining if additional adjustments are required 2 Thicker Bridge turn the ice thickness pot adjusting screw CCW one full turn Allow two cycles before determining if additional adjustments are required NOTE Never judge the thickness of the ice from the firs...

Страница 13: ...www cornelius com CORNELIUS INC ...

Отзывы: