background image

Pinnacle Hot Gas Valve Replacement Installation Instructions

© 2007-2013, IMI Cornelius Inc.

- 1 -

Publication Number: 629091023INS

SAFETY INSTRUCTIONS

S

AFETY

!

WARNING

:

Before starting installation, read and understand all safety label and warnings on the machine. Also review and 
understand all safety instructions in the owners, installation and service manuals.

Failure to comply could result in serious injury, death or damage to the equipment.

Q

UALIFIED

 S

ERVICE

 P

ERSONNEL

!

WARNING

:

Only trained and certified electrical, plumbing and refrigeration technicians should service this unit.

All wiring and plumbing must conform to national and local codes. Failure to comply could 
result in serious injury, death or equipment damage.

S

AFETY

 P

RECAUTIONS

This unit has been specifically designed to provide protection against personal injury. To ensure continued 
protection observe the following:

!

WARNING

:

Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all 
power is off to the unit before performing any work.

Failure to comply could result in serious injury, death or damage to the equipment.

CAUTION

:

!

Always be sure to keep area around the unit clean and free of clutter.

Failure to keep this area clean may result in injury or equipment damage.

Содержание FCB Pinnacle

Страница 1: ...TIONS FCB Pinnacle 2 and 4 Flavor Units Release Date March 26 2007 Publication Number 629091023INS Revision Date May 13 2013 Revision B Visit the IMI Cornelius web site at www cornelius com for all yo...

Страница 2: ...ccurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper voltage 3 inadequate wiring 4 abuse 5 accident 6 alterat...

Страница 3: ...ans should service this unit All wiring and plumbing must conform to national and local codes Failure to comply could result in serious injury death or equipment damage SAFETY PRECAUTIONS This unit ha...

Страница 4: ...ping specific to the units starting with the serial number 62 If you have a Pinnacle with a serial number beginning with 56 please order kit number 629092235 for the kit and installation instructions...

Страница 5: ...two screws from the top of the electrical box and swing it out to the side Secure the electrical box in the open position with tape 3 Attach gauges and initiate refrigerant removal 4 While charge is b...

Страница 6: ...wire connectors to compressor terminals run start and common Set red black and white wires away from hot gas valves Figure 4 D Remove insulation on bottom of pulse valves 2 each E Remove barrel inlet...

Страница 7: ...er T as shown Cut hot gas valve inlets 2 each with imp tubing cutter 9 Remove insulation on hot gas valve inlet line if present Figure 8 5 After the charge is removed and pressure has equalized remove...

Страница 8: ...091023INS 6 2007 2013 IMI Cornelius Inc 10 Carefully mark the tube cut locations on the hot gas valve inlet at 1 5 8 up from the copper hot gas header as shown Cut hot gas valve inlet line with imp tu...

Страница 9: ...007 2013 IMI Cornelius Inc 7 Publication Number 629091023INS 12 Cover area behind and under braze area with wet legs Figure 11 13 Install hot gas valve assembly provided three braze fittings 14 Wrap h...

Страница 10: ...ation Number 629091023INS 8 2007 2013 IMI Cornelius Inc 15 Push all wire harnesses aside to prevent burn damage Figure 13 16 Braze the 3 solder joints Figure 14 17 Install the new filter drier using t...

Страница 11: ...tall solenoid coils on pulse valves and hot gas valves C Re attached harness plugs to both hot gas valves and pulse valves NOTE Check to be sure the harnesses are connected to the correct components D...

Страница 12: ...Pinnacle Hot Gas Valve Replacement Installation Instructions Publication Number 629091023INS 10 2007 2013 IMI Cornelius Inc...

Страница 13: ......

Страница 14: ...IMI Cornelius Inc www cornelius com...

Отзывы: