Pinnacle Hot Gas Valve Replacement Installation Instructions
Publication Number: 629091023INS
- 4 -
© 2007-2013, IMI Cornelius Inc.
C. Remove wire connectors to compressor terminals (run, start, and common). Set red, black, and
white wires away from hot gas valves.
Figure 4.
D. Remove insulation on bottom of pulse
valves, 2 each.
E. Remove barrel inlet thermistors, 2 each,
from pulse valve outlets.
Figure 5.
F. Remove insulation on bottom of hot gas
valves, 2 each.
Figure 6.
Step
1
Step
2
Содержание FCB Pinnacle