background image

22

166240010

PARTS LIST

ITEM NO .

DESCRIPTION

200

525

725

1

Compressor (115V 60HZ)

162964053

162964011

162964011

Compressor (220V 50HZ)

162964054

162964038

----------

2

Pad, Masonite

09115

36310

36310

3

Hold--Down, Evaporator

163277001

163277002

163277002

4

Evaporator

01501

41100

41100

5

O--Ring

00122

03120

03120

6

Auger

04062

03796

03796

7

Shell, Evaporator

01508

09182

09182

8

Gasket, Evaporator Shell

01916

08666

08666

9

Washer, Thrust

08043

8043

08043

10

Plate, Gearmotor Mounting

04060

03163

03163

11

Chute, Inclined Ice

166046000

08720

08720

12

Gearmotor (Von Weiss; 115V 60HZ)

164826001

164826001

164826001

Gearmotor (Von Weiss; 220V 50HZ)

164826002

164826002

----------

13

Condenser

02908

25446

25446

14

Shroud, Condenser

161890013

36074

36074

15

Blade, Condenser Fan

165595008

25578

25578

16

Motor, Condenser Fan (115V 60HZ)

23526

25242

25242

Motor, Condenser Fan (220V 50HZ)

23645

300835000

----------

17

Bracket, Condenser Fan Motor

00260

36075

36075

18

Drier

166184001

166184001

166184001

19

Thermostat, Bin

09570

09570

09570

20

Relay, Gearmotor Start (Von Weiss; 115V 60HZ)

161627001

161627001

161627001

Relay, Gearmotor Start (Von Weiss; 220V 50HZ)

161627002

161627002

----------

21

Control, High Pressure

165677006

165677006

165677006

22

Control, Fan Switch

165677005

165677005

165677005

23

Float Tank, Complete

21789

21789

21789

24

Float Valve Only

21924

21924

21924

25

Thermowell

20773

29541

29541

26

Relay, Power (115V 60HZ)

164884002

164884002

164884002

Relay, Power (220V 50HZ)

40713

40713

----------

27

Clip, Delay Thermostat

----------

25871

25871

28

Valve, Automatic Expansion

161921004

161921004

161921004

29

Relay, Compressor Start (115V 60HZ)

161998016

161998008

161998008

Relay, Compressor Start (220V 50HZ)

161998017

161998011

----------

30

Capacitor, Compressor Start (115V 60HZ)

161165015

161165007

161165007

Capacitor, Compressor Start (220V 50HZ)

161165016

161165010

----------

31

Capacitor, Gearmotor Start (Von Weiss; 115V

60HZ)

161165000

161165000

161165000

Capacitor, Gearmotor Start (Von Weiss; 220V

50HZ)

29519

29519

----------

32

Screw, Wing

00890

00890

00890

33

Switch, On--Off/Circuit Breaker (115V 60HZ)

166220001

166220001

166220001

Switch, On--Off/Circuit Breaker (220V 50HZ)

166220000

166220000

----------

34

Disc, Centering

----------

20956

20956

35

Thermostat, Gearmotor Delay

----------

25864

25864

36

Valve, Refrigeration Service

162978003

162978003

162978003

37

Bushing, Auger Guide

02040

----------

----------

Содержание Enduro 200

Страница 1: ...r other such method as proved effective by test Water pipe connections and fixtures directly connected to a potable water supply shall be sized installed and maintained according to Federal State and...

Страница 2: ...9 DELAY THERMOSTAT 9 COMPRESSOR START RELAY 10 POTENTIAL RELAYS 10 CAPACITORS GENERAL 10 MAINTENANCE 11 SANITIZING AND CLEANING PROCEDURE 12 WATER TREATMENT 12 WINTER STORAGE 13 CLEANING THE CONDENSE...

Страница 3: ...E 7 WIRING DIAGRAM AF 200 P SC R 115 VOLTS 60 HZ 14 FIGURE 8 WIRING DIAGRAM AF 200 P SC 50 R 220 VOLTS 50 HZ 15 FIGURE 9 WIRING DIAGRAM AF525 SC R AND AF725 SC R 115 VOLTS 60 HZ 16 FIGURE 10 WIRING DI...

Страница 4: ...nt The problems of the serviceman and user have been given special attention in the development and engineering of our ice makers If you encounter a problem which is not covered in this manual please...

Страница 5: ...130 lbs 59 kgs 117 lbs 53 kgs AF 200 P SC50R PRODUCTION CHART AIR TEMPERATURE WATER TEMPERATURE 50 F 10 C 70 F 21 C 80 F 27 C 50 F 10 C 234 lbs 106 kgs 206 lbs 94 kgs 197 lbs 90 kgs 70 F 21 C 213 lbs...

Страница 6: ...0 F 27 C 50 F 10 C 654 lbs 297 kgs 588 lbs 267 kgs 552 lbs 251 kgs 70 F 21 C 639 lbs 290 kgs 563 lbs 256 kgs 521 lbs 237 kgs 90 F 27 C 562 lbs 255 kgs 479 lbs 218 kgs 448 lbs 204 kgs AF 525 P SC50R PR...

Страница 7: ...5 1 32 IN 13 CM 32 1 16 IN 81 CM 4 IN 10 CM FIGURE 3 725 SERIES SPECIFICATIONS ICE PRODUCTION CAPACITY approximate AF 725 P SCR PRODUCTION CHART AIR TEMPERATURE WATER TEMPERATURE 50 F 10 C 70 F 21 C 8...

Страница 8: ...iner provided with the unit should be installed on the down stream side of the shut off valve The supply line must be adequately sized to compensate for the lengths of the incoming water run The machi...

Страница 9: ...draw on the entire unit as well as components such as the gearmotor and fan motor J Check refrigerant circuit and all plumbing connections for leaks etc K Check bin thermostat or mechanical shut off...

Страница 10: ...will be reduced in temperature As a result freezing occurs and ice forms on the surface of the evaporator As more water is frozen the thickness of the ice increases until it exceeds the distance allo...

Страница 11: ...f cool air across it which removes much of the heat from the hot refrigerant vapor As the vapor passing through the condenser loses heat it condenses back to a liquid since it is still under high pres...

Страница 12: ...ng power to the machine HIGH PRESSURE CONTROL Switch contact will open at 450 PSI for R404a breaking the circuit to the compressor This control is manually resetable GEARMOTOR START RELAY This is a cu...

Страница 13: ...1 2 times the supply voltage This voltage sets up a magnetic field which causes the relay to operate The starting relay is calibrated to remove the start capacitor open the start ing circuit at approx...

Страница 14: ...k If the Helix auger on the corkscrew auger round bar becomes flat on the inside more than 1 8 of an inch over a length of two inches or more it should be replaced NOTE HELIX AUGERS DO HAVE MACHINED F...

Страница 15: ...lution and allow them to soak for 10 minutes 9 Using a clean cloth and the sanitizing solution wipe down the interior of the ice chute thermowell door tracks ice bin top and around bin opening Allow t...

Страница 16: ...ch com pressed air hose Start machine As head pressure reaches the appropriate level opening the water regulating valve the compressed air will force the water out Do not let the machine operate longe...

Страница 17: ...165 VAC RD RD BK 4 3 2 WH BK START RELAY GEAR MOTOR FAN SWITCH C O 205 C I 275 GR BK BIN BL BL HIGH PRESS CNTRL C O 450 PSIG MANUAL RESET THERMOSTAT 2 1 3 YL 5 RD R S C COMPRESSOR 1 BK BK OVERLOAD COM...

Страница 18: ...BL 3 4 2 BL START RELAY GEAR MOTOR FAN SWITCH C O 205 C I 275 BR LB GN Y BIN BL BL HIGH PRESS CNTRL C O 450 PSIG MANUAL RESET THERMOSTAT 2 M RD 1 S YL R C BK S COMPRESSOR GN Y 1 BK RD OVERLOAD COMPRE...

Страница 19: ...THERMOSTAT DELAY BL RD START RELAY GEAR MOTOR FAN SWITCH C I 275 C O 205 WH GW BL BIN BL RD CONTROL THERMOSTAT R YL S COMPRESSOR C 1 5 2 1 BK BL BK OVERLOAD COMPRESSOR POTENTIAL START RELAY RD BL BL R...

Страница 20: ...CITOR GEAR MOTOR RD RD BK 3 2 BK BL THERMOSTAT DELAY BK RD START RELAY GEAR MOTOR FAN SWITCH BK GW BIN RD YL BL CONTROL THERMOSTAT RD R C YL GW S 1 COMPRESSOR BK RD RD CONTACTOR COMPRESSOR OVERLOAD BL...

Страница 21: ...or starting capacitor E Check and replace F Loose electrical connection F Check wiring MAKING WET ICE A Surrounding air temperature too high A Correct or move unit B High water level in float reservoi...

Страница 22: ...ath of ice B Adjust thermowell UNIT OFF ON RESET A Ice jams up in evaporator shell A Clean inside surface of evaporator shell B Bin thermostat will not shut off machine Set too cold B Check and adjust...

Страница 23: ...aces causing thicker flaked ice to be made L Replace auger M Auger out of line causing excessive wear on the lower outside surface where it rubs against evaporator shell liner at the bottom M Replace...

Страница 24: ...21 166240010 ILLUSTRATED PARTS BREAKDOWN SERIES 525 725 1 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 FIGURE 11 PARTS BREAKDOWN...

Страница 25: ...5V 60HZ 161627001 161627001 161627001 Relay Gearmotor Start Von Weiss 220V 50HZ 161627002 161627002 21 Control High Pressure 165677006 165677006 165677006 22 Control Fan Switch 165677005 165677005 165...

Страница 26: ...20 09120 09120 36555 2 Door Track LH 25007 25007 25007 25007 25007 3 Door Track RH 08824 08824 08824 08824 08824 4 Door Trim 09112 09112 09112 09112 08681 5 Back Panel 163278001 25043 N A N A N A 6 Fr...

Страница 27: ...the ice machine normal prescribed maintenance cleaning adjustments and ice purchases are the responsibility of the original owner No parts warranty or labor allowance on the motor compressor assembly...

Страница 28: ...One Cornelius Place Anoka Minnesota 55303 6234 763 421 6120 800 238 3600 Corporate Headquarters IMI CORNELIUS INC...

Отзывы: