background image

11

166240010

MAINTENANCE

THE FOLLOWING MAINTENANCE SHOULD BE PERFORMED AT LEAST EVERY SIX MONTHS ON

FLAKED ICE MACHINES:

1. Check power supply with machine running for proper voltage.

2. Check water level in the float tank reservoir. Water level should be maintained at the top of the evaporator.

Adjust if necessary. (See illustration and adjustment procedure)

3. Clean the air--cooled condenser coil with a stiff brush or vacuum cleaner (See procedure)

CAUTION:

CONDENSER COOLING FINS ARE SHARP, USE CARE WHEN CLEANING.

4. Clean the ice storage bin and flush the bin drain at least once a month.

5. If a water conditioner is installed in the inlet water line, change, replace, or clean the filter, strainer or car-

tridge as required.

6. If heavy mineral deposits on the auger and evaporator shell are encountered due to bad local water condi-

tions, follow sanitizing and cleaning procedure.

7. Loosen hold--down cam locks and remove gearmotor assembly.

8. Check thrust washer; replace if noticeably worn.

9. Lift out auger and examine for wear. The corkscrew auger guide bushing pressed into the drive block

should be checked for wear. Replace if loose or if worn flat with auger drive block. If the Helix auger on the

corkscrew auger round bar becomes flat on the inside more than 1/8 of an inch over a length of two inches

or more it should be replaced.

NOTE:

HELIX AUGERS DO HAVE MACHINED FLAT RELIEF SURFACES. DON’T CONFUSE THEM WITH

WORN FLAT AREAS.

Check the insert in the bottom ring of the Helix auger and replace if excessively worn.

10. Check shell vertical strips for wear. Replace the shell if excessive wear is shown.

11. Check O--Ring, replace if worn or cut.

12. Re--assemble, steps 7 through 11.

CAUTION: IN RE--ASSEMBLING THE AUGER GEARMOTOR, THE HOLD DOWN CLAMPS

MUST BE RIGHT AND SECURE. IN RE--INSTALLING THE EVAPORATOR SHELL, BE

ABSOLUTELY SURE THAT THE ”O” RING IS NOT PINCHED OFF AS THIS WOULD CAUSE A

WATER LEAK AROUND THE BASE OF THE EVAPORATOR. LUBRICATE THE ”O” RING WITH FOOD

GRADE LUBRICANT BEFORE RE--ASSEMBLING SHELL. IN RE--ASSEMBLING THE AUGER

GEARMOTOR, THE HOLD DOWN CLAMPS MUST BE RIGHT AND SECURE. IN RE--INSTALLING THE

EVAPORATOR SHELL, BE ABSOLUTELY SURE THAT THE ”O” RING IS NOT PINCHED OFF AS THIS

WOULD CAUSE A WATER LEAK AROUND THE BASE OF THE EVAPORATOR. LUBRICATE THE ”O”

RING WITH FOOD GRADE LUBRICANT BEFORE RE--ASSEMBLING SHELL.

13. Check for alignment of ice chute. Make sure chute gasket is not blocking path of ice flow.

14. Check bin thermostat operation. In the mid--range position the bin thermostat will open at 42

°

and has a 6

°

differential.

Содержание Enduro 200

Страница 1: ...r other such method as proved effective by test Water pipe connections and fixtures directly connected to a potable water supply shall be sized installed and maintained according to Federal State and...

Страница 2: ...9 DELAY THERMOSTAT 9 COMPRESSOR START RELAY 10 POTENTIAL RELAYS 10 CAPACITORS GENERAL 10 MAINTENANCE 11 SANITIZING AND CLEANING PROCEDURE 12 WATER TREATMENT 12 WINTER STORAGE 13 CLEANING THE CONDENSE...

Страница 3: ...E 7 WIRING DIAGRAM AF 200 P SC R 115 VOLTS 60 HZ 14 FIGURE 8 WIRING DIAGRAM AF 200 P SC 50 R 220 VOLTS 50 HZ 15 FIGURE 9 WIRING DIAGRAM AF525 SC R AND AF725 SC R 115 VOLTS 60 HZ 16 FIGURE 10 WIRING DI...

Страница 4: ...nt The problems of the serviceman and user have been given special attention in the development and engineering of our ice makers If you encounter a problem which is not covered in this manual please...

Страница 5: ...130 lbs 59 kgs 117 lbs 53 kgs AF 200 P SC50R PRODUCTION CHART AIR TEMPERATURE WATER TEMPERATURE 50 F 10 C 70 F 21 C 80 F 27 C 50 F 10 C 234 lbs 106 kgs 206 lbs 94 kgs 197 lbs 90 kgs 70 F 21 C 213 lbs...

Страница 6: ...0 F 27 C 50 F 10 C 654 lbs 297 kgs 588 lbs 267 kgs 552 lbs 251 kgs 70 F 21 C 639 lbs 290 kgs 563 lbs 256 kgs 521 lbs 237 kgs 90 F 27 C 562 lbs 255 kgs 479 lbs 218 kgs 448 lbs 204 kgs AF 525 P SC50R PR...

Страница 7: ...5 1 32 IN 13 CM 32 1 16 IN 81 CM 4 IN 10 CM FIGURE 3 725 SERIES SPECIFICATIONS ICE PRODUCTION CAPACITY approximate AF 725 P SCR PRODUCTION CHART AIR TEMPERATURE WATER TEMPERATURE 50 F 10 C 70 F 21 C 8...

Страница 8: ...iner provided with the unit should be installed on the down stream side of the shut off valve The supply line must be adequately sized to compensate for the lengths of the incoming water run The machi...

Страница 9: ...draw on the entire unit as well as components such as the gearmotor and fan motor J Check refrigerant circuit and all plumbing connections for leaks etc K Check bin thermostat or mechanical shut off...

Страница 10: ...will be reduced in temperature As a result freezing occurs and ice forms on the surface of the evaporator As more water is frozen the thickness of the ice increases until it exceeds the distance allo...

Страница 11: ...f cool air across it which removes much of the heat from the hot refrigerant vapor As the vapor passing through the condenser loses heat it condenses back to a liquid since it is still under high pres...

Страница 12: ...ng power to the machine HIGH PRESSURE CONTROL Switch contact will open at 450 PSI for R404a breaking the circuit to the compressor This control is manually resetable GEARMOTOR START RELAY This is a cu...

Страница 13: ...1 2 times the supply voltage This voltage sets up a magnetic field which causes the relay to operate The starting relay is calibrated to remove the start capacitor open the start ing circuit at approx...

Страница 14: ...k If the Helix auger on the corkscrew auger round bar becomes flat on the inside more than 1 8 of an inch over a length of two inches or more it should be replaced NOTE HELIX AUGERS DO HAVE MACHINED F...

Страница 15: ...lution and allow them to soak for 10 minutes 9 Using a clean cloth and the sanitizing solution wipe down the interior of the ice chute thermowell door tracks ice bin top and around bin opening Allow t...

Страница 16: ...ch com pressed air hose Start machine As head pressure reaches the appropriate level opening the water regulating valve the compressed air will force the water out Do not let the machine operate longe...

Страница 17: ...165 VAC RD RD BK 4 3 2 WH BK START RELAY GEAR MOTOR FAN SWITCH C O 205 C I 275 GR BK BIN BL BL HIGH PRESS CNTRL C O 450 PSIG MANUAL RESET THERMOSTAT 2 1 3 YL 5 RD R S C COMPRESSOR 1 BK BK OVERLOAD COM...

Страница 18: ...BL 3 4 2 BL START RELAY GEAR MOTOR FAN SWITCH C O 205 C I 275 BR LB GN Y BIN BL BL HIGH PRESS CNTRL C O 450 PSIG MANUAL RESET THERMOSTAT 2 M RD 1 S YL R C BK S COMPRESSOR GN Y 1 BK RD OVERLOAD COMPRE...

Страница 19: ...THERMOSTAT DELAY BL RD START RELAY GEAR MOTOR FAN SWITCH C I 275 C O 205 WH GW BL BIN BL RD CONTROL THERMOSTAT R YL S COMPRESSOR C 1 5 2 1 BK BL BK OVERLOAD COMPRESSOR POTENTIAL START RELAY RD BL BL R...

Страница 20: ...CITOR GEAR MOTOR RD RD BK 3 2 BK BL THERMOSTAT DELAY BK RD START RELAY GEAR MOTOR FAN SWITCH BK GW BIN RD YL BL CONTROL THERMOSTAT RD R C YL GW S 1 COMPRESSOR BK RD RD CONTACTOR COMPRESSOR OVERLOAD BL...

Страница 21: ...or starting capacitor E Check and replace F Loose electrical connection F Check wiring MAKING WET ICE A Surrounding air temperature too high A Correct or move unit B High water level in float reservoi...

Страница 22: ...ath of ice B Adjust thermowell UNIT OFF ON RESET A Ice jams up in evaporator shell A Clean inside surface of evaporator shell B Bin thermostat will not shut off machine Set too cold B Check and adjust...

Страница 23: ...aces causing thicker flaked ice to be made L Replace auger M Auger out of line causing excessive wear on the lower outside surface where it rubs against evaporator shell liner at the bottom M Replace...

Страница 24: ...21 166240010 ILLUSTRATED PARTS BREAKDOWN SERIES 525 725 1 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 FIGURE 11 PARTS BREAKDOWN...

Страница 25: ...5V 60HZ 161627001 161627001 161627001 Relay Gearmotor Start Von Weiss 220V 50HZ 161627002 161627002 21 Control High Pressure 165677006 165677006 165677006 22 Control Fan Switch 165677005 165677005 165...

Страница 26: ...20 09120 09120 36555 2 Door Track LH 25007 25007 25007 25007 25007 3 Door Track RH 08824 08824 08824 08824 08824 4 Door Trim 09112 09112 09112 09112 08681 5 Back Panel 163278001 25043 N A N A N A 6 Fr...

Страница 27: ...the ice machine normal prescribed maintenance cleaning adjustments and ice purchases are the responsibility of the original owner No parts warranty or labor allowance on the motor compressor assembly...

Страница 28: ...One Cornelius Place Anoka Minnesota 55303 6234 763 421 6120 800 238 3600 Corporate Headquarters IMI CORNELIUS INC...

Отзывы: