background image

                               

Ice/Beverage Dispenser Operator’s Manual      

© 2004-2010, IMI Cornelius Inc.

- 5 -

Publication Number: 620917901OPR

2.

Remove ice from hopper and clean and sanitize the hopper. (See the Cleaning the interior surfaces section 
shown later in this manual).

3.

While cleaning the hopper use the brush provided with the unit to clean the cold plate surface. To accom-
plish this, the brush needs to be extended through the opening in the bottom of the hopper.

Y

EARLY

 M

AINTENANCE

:

Have the water pump and check valve inspected and cleaned by a qualified service technician. 

Have the CO

2

 gas check valve inspected and cleaned by a qualified service technician.

Remove the unit’s splash and cold plate cover to clean and sanitize the cold plate surface. (See the cleaning the 
cold plate section shown later in this manual).

Cleaning Interior Surfaces (Monthly Cleaning)

CAUTION:

!

When pouring liquid into the hopper, do not exceed the rate of 1/2 gallon per minute. Pouring more liquid into the 
hopper could result in an overflow situation may result in injury or damage to the equipment.

1.

Remove agitator assembly.

2.

Using a nylon bristle brush or sponge, clean the interior of the hopper, top cover and agitator assembly with  
soap solution. Thoroughly rinse the hopper, cover and agitator surfaces with clean potable water.

3.

Reassemble agitator assembly. Take special care to ensure that the thumbscrew is tight.

4.

Using a mechanical spray bottle filled with sanitizing solution, spray the entire interior and agitator assem-
bly. Allow to air dry.

5.

Remove merchandiser and ice chute cover from unit.

6.

With a nylon bristle brush or sponge, clean the inside of the ice chute, gasket, and cover with soap solution 
and rinse thoroughly to remove all traces of detergent.

7.

Reassemble ice chute assembly.

8.

Using a mechanical spray bottle filled with sanitizing solution, spray the inside of the ice chute. Allow to air dry.

9.

Reinstall merchandiser.

Cold Plate (Yearly Maintenance)

1.

Remove splash panel.

2.

Remove or move the plastic cold plate cover to expose the cold plate.

3.

Locate and remove any debris from the drain trough. Check that the drain holes are not clogged.

4.

Pour small amount of soap solution through cold plate openings in hopper.

5.

Using a cloth, wash down the surfaces of the cold plate and plastic cover with soap solution. 

6.

Install and properly position the access covers on the cold plate.

7.

Install the splash panel in the reverse order it was removed.

8.

Rinse cold plate surface by pouring potable water through hopper openings.

Dispensing Valves: ( Daily Cleaning)

Refer to addendum supplied with the unit that is applicable to the manufacturer of the valves installed on the unit.

Product Tubing (Monthly Cleaning)

IMPORTANT: Only trained and qualified persons should perform these cleaning and sanitizing procedures.

Sanitize Pre-Mix And Post–Mix Tank System

1.

Remove all the quick disconnects from all the tanks. Fill a suitable pail or bucket with soap solution.

Содержание Enduro 175 8 Valve

Страница 1: ...MODEL ENDURO 175 8 VALVE OPERATOR S MANUAL Release Date March 1 2004 Publication Number 620917901OPR Revision Date August 3 2010 Revision C Visit the IMI Cornelius web site at www cornelius com for al...

Страница 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Страница 3: ...Drink Dispenser 3 CLEANING AND MAINTENANCE INSTRUCTIONS 4 Daily Cleaning 4 Daily Maintenance 4 Weekly Cleaning In addition to daily procedures 4 Monthly Cleaning In addition to daily and weekly proce...

Страница 4: ......

Страница 5: ...moderate injury or equipment damage SAFETY TIPS Carefullyreadandfollowall safety messages inthismanualandsafety signsontheunit Keepsafety signsin goodconditionandreplace missingordamageditems Learnho...

Страница 6: ...ill cause residual sanitizing solution or water remaining inside the unit to freeze resulting in damage to internal components CO2 CARBON DIOXIDE WARNING DANGER CO2 displaces oxygen Strict attention M...

Страница 7: ...of large chunks of ice which jam up inside the hopper will cause failure if the agitator motor and damage to the hopper If bagged ice is used it must be carefully and completely broken into small cube...

Страница 8: ...e with clean water and allow to air dry 3 Remove valve nozzles and diffusers and wash in warm soapy water rinse in clean water and allow to air dry 4 Clean the interior of the ice chute using the brus...

Страница 9: ...s tight 4 Using a mechanical spray bottle filled with sanitizing solution spray the entire interior and agitator assem bly Allow to air dry 5 Remove merchandiser and ice chute cover from unit 6 With a...

Страница 10: ...product syrup tanks Operate the valves until all sanitizer has been flushed from the system and only product syrup is flowing Sanitize syrup lines B I B Systems 1 Remove all the quick disconnects from...

Страница 11: ...ff a CO2 regulator can cause serious personnel injury or death could occur 4 Position the full CO2 cylinder and secure with a safety chain 5 Make sure gasket is in place inside the CO2 regulator assem...

Страница 12: ...TURN A No power B Bent depressor plate does not actuate switch C Defective dispensing switch GATE DOES NOT OPEN OR IS SLUGGISH AGITATOR TURNS A Defective gate solenoid B Excessive pressure against ga...

Страница 13: ...r for additional information and troubleshooting of beverage system FLAVOR DISPENSES FOR MORE THAN 1 SEC A Dip switch settings on control board incorrect B PC board defective C Defective flow control...

Страница 14: ...Ice Beverage Dispenser Operator s Manual Publication Number 620917901OPR 10 2004 2010 IMI Cornelius Inc...

Страница 15: ......

Страница 16: ...IMI Cornelius Inc www cornelius com...

Отзывы: