background image

Ice/Beverage Dispenser Operator’s Manual                              

Publication Number: 620917901OPR

- 2 -

© 2004-2010, IMI Cornelius Inc.

S

AFETY

 P

RECAUTIONS

This unit has been specifically designed to provide protection against personal injury. To ensure continued protection 
observe the following:

!

WARNING:

Disconnect power to the unit before servicing following all lock out/tag out procedures established by the user. Verify 
all of the power is off to the unit before any work is performed.

Failure to disconnect the power could result in serious injury, death or equipment damage.

CAUTION:

!

Always be sure to keep area around the unit clean and free of clutter. Failure to keep this area clean may result in 
injury or equipment damage.

S

HIPPING

 A

ND

 S

TORAGE

CAUTION:

!

Before shipping, storing, or relocating the unit, the unit must be sanitized and all sanitizing solution must be drained 
from the system. A freezing ambient environment will cause residual sanitizing solution or water remaining inside the 
unit to freeze resulting in damage to internal components.

CO

2

 (C

ARBON

 D

IOXIDE

) W

ARNING

!

DANGER:

CO

2

 displaces oxygen. Strict attention MUST be observed in the prevention of CO

2

 gas leaks in the entire CO

2

 and 

soft drink system. If a CO

2

 gas leak is suspected, particularly in a small area, IMMEDIATELY ventilate the 

contaminated area before attempting to repair the leak. Personnel exposed to high concentrations of CO

2

 gas 

experience tremors which are followed rapidly by loss of consciousness and DEATH.

M

OUNTING

 

IN

 

OR

 

ON

 

A

 C

OUNTER

!

WARNING:

When installing the unit in or on a counter top, the counter must be able to support a weight in excess of 415 lbs.

 

to 

insure adequate support for the unit. FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR 
EQUIPMENT DAMAGE.

NOTE:  Many units incorporate the use of additional equipment such as icemakers. When any addition 

equipment is used you must check with the equipment manufacturer to determine the addi-
tional weight the counter will need to support to ensure a safe installation.

Содержание Enduro 175 8 Valve

Страница 1: ...MODEL ENDURO 175 8 VALVE OPERATOR S MANUAL Release Date March 1 2004 Publication Number 620917901OPR Revision Date August 3 2010 Revision C Visit the IMI Cornelius web site at www cornelius com for al...

Страница 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Страница 3: ...Drink Dispenser 3 CLEANING AND MAINTENANCE INSTRUCTIONS 4 Daily Cleaning 4 Daily Maintenance 4 Weekly Cleaning In addition to daily procedures 4 Monthly Cleaning In addition to daily and weekly proce...

Страница 4: ......

Страница 5: ...moderate injury or equipment damage SAFETY TIPS Carefullyreadandfollowall safety messages inthismanualandsafety signsontheunit Keepsafety signsin goodconditionandreplace missingordamageditems Learnho...

Страница 6: ...ill cause residual sanitizing solution or water remaining inside the unit to freeze resulting in damage to internal components CO2 CARBON DIOXIDE WARNING DANGER CO2 displaces oxygen Strict attention M...

Страница 7: ...of large chunks of ice which jam up inside the hopper will cause failure if the agitator motor and damage to the hopper If bagged ice is used it must be carefully and completely broken into small cube...

Страница 8: ...e with clean water and allow to air dry 3 Remove valve nozzles and diffusers and wash in warm soapy water rinse in clean water and allow to air dry 4 Clean the interior of the ice chute using the brus...

Страница 9: ...s tight 4 Using a mechanical spray bottle filled with sanitizing solution spray the entire interior and agitator assem bly Allow to air dry 5 Remove merchandiser and ice chute cover from unit 6 With a...

Страница 10: ...product syrup tanks Operate the valves until all sanitizer has been flushed from the system and only product syrup is flowing Sanitize syrup lines B I B Systems 1 Remove all the quick disconnects from...

Страница 11: ...ff a CO2 regulator can cause serious personnel injury or death could occur 4 Position the full CO2 cylinder and secure with a safety chain 5 Make sure gasket is in place inside the CO2 regulator assem...

Страница 12: ...TURN A No power B Bent depressor plate does not actuate switch C Defective dispensing switch GATE DOES NOT OPEN OR IS SLUGGISH AGITATOR TURNS A Defective gate solenoid B Excessive pressure against ga...

Страница 13: ...r for additional information and troubleshooting of beverage system FLAVOR DISPENSES FOR MORE THAN 1 SEC A Dip switch settings on control board incorrect B PC board defective C Defective flow control...

Страница 14: ...Ice Beverage Dispenser Operator s Manual Publication Number 620917901OPR 10 2004 2010 IMI Cornelius Inc...

Страница 15: ......

Страница 16: ...IMI Cornelius Inc www cornelius com...

Отзывы: