CH550 and CH551 Chiller Operator’s & Installation Manual

© 2002-2010, IMI Cornelius Inc.

- 7 -

Publication Number: 91272

PARTS LIST

Figure 8. Cabinet Section Exploded View

Table 1. Cabinet Section

Item 

No.

Part No.

Name

1

31934

Switch, Illuminated (CH550), 115V

31935

Switch, Illuminated (CH551), 230V

2

32386

Thermostat, Eliwell No. EWPC902

3

620603708

Blade, Fan

4

620603711

Motor, Fan (CH550), 115V

620603709

Motor, Fan (CH551), 230V

5

*

Condenser

6

Not  Used

7

620603701

Compressor, (CH550), 115V

620603702

Compressor, (CH551), 230V

8

*

Relay

9

*

Capacitor

10

61058

TXV

11

60514

Sight Glass

12

60502

Control, Low Pressure

13

61002

Filter Drier

14

*

Reciever

15

Not Used

16

*

Pump, Circulating

17

32378

Transformer, Thermostat

18

32606

Contactor, Relay 115V

32607

Contactor, Relay 230V

Table 1. Cabinet Section

Item 

No.

Part No.

Name

Содержание CH 551

Страница 1: ...550 AND CH551 Operator s Installation Manual Release Date August 9 2002 Publication Number 91272 Revision Date May 10 2010 Revision D Visit the IMI Cornelius web site at www cornelius com for all your...

Страница 2: ...n trained and are skilled in working with electrical plumbing pneumatic and mechanical equipment It is assumed that appropriate safety precautions are taken and that all local safety and construction...

Страница 3: ...tart Up Operation 2 Thermostat 2 Temperature Controller 2 Standard Thermostat Eliwell IC902 3 Maintenance 3 Service 3 Removing Wrapper 3 Replacing Swtich 3 Replacing Thermostat 4 Replacing Fan Blade a...

Страница 4: ......

Страница 5: ...r to the tank Control temperature is sensed on the outlet of the chiller for closed loop systems and it is sensed on the inlet of the chiller for tank cooling systems The pump options consist of a sma...

Страница 6: ...ans of conduit from the junction box in the rear of the chiller cabinet to a properly fused disconnect of proper amperage or 2 Wired to a properly rated power cord and plugged into an outlet with appr...

Страница 7: ...hen it is not being used 3 Always ensure that all air inlets and outlets are free of obstructions MAINTENANCE The chiller requires very little normal maintenance The condenser fins should be cleaned b...

Страница 8: ...ving Wrapper 2 Remove the screws securing the fan guard to the fan shroud 3 Remove the conduit connection at the back of the motor and disconnect the wire leads 4 Remove the bolts securing the fan mou...

Страница 9: ...ble De Ionized Water 1 5 Meg ohms Acceptable De Ionized Water 5 Meg ohms Acceptable with Stainless Steel PVC only No Copper or Brass Propylene Glycol Lab Industrial Grade Acceptable 30 Glycol 70 Water...

Страница 10: ...ne to or from chiller is restricted B Low water level C Inoperable pump A Inspect lines and remove any obstructions B Ensure that tank is full C Check for obstruction or binding impeller replace pump...

Страница 11: ...hermostat Eliwell No EWPC902 3 620603708 Blade Fan 4 620603711 Motor Fan CH550 115V 620603709 Motor Fan CH551 230V 5 Condenser 6 Not Used 7 620603701 Compressor CH550 115V 620603702 Compressor CH551 2...

Страница 12: ...hat all equipment and parts are free from defects in material and workmanship under normal use and service For a copy of the warranty applicable to your Cornelius or Wilshire product in your country p...

Страница 13: ......

Страница 14: ...IMI Cornelius Inc www cornelius com...

Отзывы: