Corken B166 Скачать руководство пользователя страница 7

Figure 2.1: Typical installation.

Features of the T166 Automatic 
External Bypass Valve

The CORKEN T166 external bypass valve is designed 
for use with truck pumps. It controls the pump 
discharge pressure and bypasses excess liquid back 
to the truck tank.

This bypass valve can also be used in stationary 
applications utilizing sliding vane pumps.

Chapter 2—Installation of the T166 
Automatic External Bypass Valve

Proper installation ensures optimum performance of the 
pump and external bypass valve. Install the T166 external 
bypass valve on the discharge side of the pump in either 
a vertical or horizontal position. The discharge piping of 
the bypass valve typically connects to the vapor section 
of the truck tank using a back check valve. A typical truck 
installation is shown in Figure 2.1. The recommended 
pipe size for the discharge line is given in the table below. 
For distances of 50 feet or more, the next larger pipe size 
should be used.

Stationary applications with internal relief valves: 
When the T166 external bypass valve is used for vapor 
venting, the piping should be the same size used with the 
B166 external bypass valve. 

To ensure optimum performance of the external bypass 
valve and the entire pumping system, follow the instructions 
in this manual.

Pipe Size for the Discharge Line

Flow Rate

Pipe Size by Model Number

T166-1.25

T166-1.5

Up to 80 GPM

1-1/4"

Up to 100 GPM

1-1/2"

2 .1 Operation of the T166 
Automatic External Bypass Valve

Truck Applications:

The differential pressure setting of the B166 external bypass 
valve is adjustable. The range of differential pressure 
depends on the size of the spring installed in the bypass 
valve. When the bypass valve ships from the CORKEN 
factory, a tag identifying the spring size is attached to the 
valve bonnet. The table below shows the part number 
and differential pressure range for each spring. All of the 
springs are interchangeable with each valve size.

Valve Model

Spring Number

Differential Pressure 

(PSIG)

T166

1138

25–60

1193

50–150

1193

100–225

1313

1.  Install liquid-filled pressure gauges equipped with a 

needle valve or snubber in the following locations:

a. Pump discharge gauge port or Inlet side of the 

bypass valve.

b.  Supply tank and/or pump suction.

Bypass Valve

Pump

7

Содержание B166

Страница 1: ...f Corken products must be made only by experienced trained and qualified personnel 3 Maintenance use and installation of Corken products must comply with Corken instructions applicable laws and safety...

Страница 2: ...ties including any implied warranty of merchantability or fitness for a particular purpose are expressly negated to the extent permitted by law and shall in no event extend beyond the expressed warran...

Страница 3: ...1 Operation of the B166 External Automatic Bypass Valve 5 FEATURES OF THE T166 AUTOMATIC EXTERNAL BYPASS VALVE 7 CHAPTER 2 INSTALLATION OF THE T166 AUTOMATIC EXTERNAL BYPASS VALVE 7 2 1 Operation of...

Страница 4: ...mance of the valve Sound Levels These products are reactionary devices used in pumping systems Sound levels are highly dependent upon the application product being pumped and installation When operati...

Страница 5: ...e below For distances of 50 feet or more the next larger pipe size should be used Pipe Sizes for Discharge Line Flow Rate Pipe Size by Model Number B166B 75 B166B 1 Up to 30 GPM 3 4 Up to 40 GPM 1 1 1...

Страница 6: ...6 9 8 6 bar higher than the starting pressure EXAMPLE The starting pressure is 125 psi 8 6 bar After starting the pump it increases to 150 psi 10 3 bar and adjusts to a maximum pressure of 235 psi 16...

Страница 7: ...bypass valve is used for vapor venting the piping should be the same size used with the B166 external bypass valve To ensure optimum performance of the external bypass valve and the entire pumping sys...

Страница 8: ...external bypass valve should be set 20 25 psi 1 38 to 1 72 bar below the setting of the pump s internal relief valve Following this guideline ensures the liquid does not recirculate through the intern...

Страница 9: ...4 1 Springs 25 60 psig differential range No charge option A 50 150 psig differential range No charge option B 100 225 psig differential range No charge option C O ring Material Buna N Standard A Neop...

Страница 10: ...lling pumps and aerosol propellant feed pumps T166 Used with truck pumps and multi cylinder filling pumps Part Model Standard Material Optional Material Valve body B166 T166 Ductile iron ASTM 536 60 4...

Страница 11: ...Appendix D Outline Dimensions for Model B166 All dimensions are in inches centimeters 1 438 3 7 1 750 4 4 1 375 3 5 1 375 3 5 2 105 5 3 7 926 20 1 3 4 NPT 3 4 NPT 11...

Страница 12: ...D Outline Dimensions for Model T166 All dimensions are in inches centimeters 8 3 32 20 52 1 5 16 3 33 2 7 16 6 19 1 5 16 3 33 1 5 16 3 33 1 5 16 3 33 Pipe tap options T166 1 25 1 1 4 NPT T166 1 5 1 1...

Страница 13: ...Spring seal 1 7 2 217b O ring 1 8 1138 Relief spring 25 60 psi 1 1193 Relief spring 50 150 psi 1 9 1193 Relief springs 100 225 psi 1 1313 1 10 1251 Valve 1 Ref No Part No Description Qty 11 1139 Ball...

Страница 14: ...87A Socket head 3 8 16 X 7 8 gr 8 4 6 1136 Spring seal 1 7 2 217_b O ring 1 8 1138 Spring 25 to 60 psi 1 1193 Spring 50 to 150 psi 1 9 1193 Spring 100 to 225 psi 1 1313 1 Ref No Part No Description Qt...

Страница 15: ...15...

Страница 16: ...6 CORKEN INC A Unit of IDEX Corporation 3805 N W 36th St Oklahoma City OK 73112 Phone 405 946 5576 Fax 405 948 7343 Visit our website at http www corken com or e mail us at cocsalesdept idexcorp com S...

Отзывы: