Applicable Notices for ATEX 
2014/34/EU Conformity

Product Type:

Corken Liquid Transfer Bypass Valves

Model Covered: 

T166 ONLY

Intended Application:

The bypass valve models covered by this manual conform to 
the European Union ATEX 2014/34/EU Directive for explosive 
gas atmospheres and transfer of liquefied gases such as 
Liquefied Petroleum Gas, anhydrous ammonia, freons, etc.

Possible Misuse Warning:

The designated bypass valve models must only be 
installed in systems designed for its intended use, similar 
to the examples presented in this manual.

ATEX Classification:

Group II; Category 2; G; Temperature Class T4 – T5

These products are classified under the ATEX directive 
as Equipment – Group II – Category 2 – equipment is 
intended for use in areas where explosive atmospheres 
caused by gases or vapors (G) may be present. The 
surface Temperature Class rating is a range between T4 
275°F (135°C) and T5 212°F (100°C).

Nameplate:

Training Instructions:

Instructions for the safe application and use of this product 
are provided in this manual. Read this manual completely 
prior to installation and use of this product. Only qualified 
and properly trained personnel should be allowed to install, 
operate, and maintain this equipment.

Mechanical Ignition Sources:

The bypass valve is installed as part of an assembly including 
the pump and the entire system must be grounded to prevent 
possible electrostatic discharge. Installation and adjustment  
guidelines are provided in this manual and are to be followed 
for the proper operation and performance of the valve.

Sound Levels:

These products are reactionary devices used in pumping 
systems. Sound levels are highly dependent upon the 
application, product being pumped, and installation. When 
operating in the system the valves should have a noise 
level no higher than 80 dBA.

Piping Forces and Moments:

Maximum Allowable Nozzle Forces and Moments
Note: Piping systems should be designed according to 
standard engineering practice and applicable national 
and local codes. NO piping induced forces or moments 
are recommended for Corken T166 bypass valves.

X—Horizontal (perpendicular to valve discharge port)
Y—Vertical
Z—Horizontal (parallel to valve discharge port)

Fx = Fy = Fz = 42 lb (19 kg)
Mx = My = Mz = 70 ft•lb (10 kg•m)

Notice!

Corken bypass valves should only be installed in LPG 
& NH

3

 systems that have been designed by qualified 

engineering personnel and operated and maintained 
by qualified technicians. The system must conform to 
all applicable local and national regulations and safety 
standards (specifically, LPG systems 

must conform to 

NFPA 58). This manual 

must be kept with the bypass 

valves and be reviewed 

before installing, operating or 

performing any maintenance work.

Warning!

Do not attempt to open the pump or bypass valve until you 
have bled off the pressure. High pressure in the system 
can cause personal injury and/or property damage. 
Please note: if the system contains a meter, the differential 
valve will keep liquid under pressure in the pump, meter 
and piping even after the hose has been emptied.

File number

ATEX and

machinery

directive

Explosion

protection

ATEX Directive

2014/34/EU marking

Equipment classified

as Group II—Catagory 2

Explosion gas

atmosphere high level

Surface temperature

range T4

(135°C) 275°F

4

Содержание B166

Страница 1: ...f Corken products must be made only by experienced trained and qualified personnel 3 Maintenance use and installation of Corken products must comply with Corken instructions applicable laws and safety...

Страница 2: ...ties including any implied warranty of merchantability or fitness for a particular purpose are expressly negated to the extent permitted by law and shall in no event extend beyond the expressed warran...

Страница 3: ...1 Operation of the B166 External Automatic Bypass Valve 5 FEATURES OF THE T166 AUTOMATIC EXTERNAL BYPASS VALVE 7 CHAPTER 2 INSTALLATION OF THE T166 AUTOMATIC EXTERNAL BYPASS VALVE 7 2 1 Operation of...

Страница 4: ...mance of the valve Sound Levels These products are reactionary devices used in pumping systems Sound levels are highly dependent upon the application product being pumped and installation When operati...

Страница 5: ...e below For distances of 50 feet or more the next larger pipe size should be used Pipe Sizes for Discharge Line Flow Rate Pipe Size by Model Number B166B 75 B166B 1 Up to 30 GPM 3 4 Up to 40 GPM 1 1 1...

Страница 6: ...6 9 8 6 bar higher than the starting pressure EXAMPLE The starting pressure is 125 psi 8 6 bar After starting the pump it increases to 150 psi 10 3 bar and adjusts to a maximum pressure of 235 psi 16...

Страница 7: ...bypass valve is used for vapor venting the piping should be the same size used with the B166 external bypass valve To ensure optimum performance of the external bypass valve and the entire pumping sys...

Страница 8: ...external bypass valve should be set 20 25 psi 1 38 to 1 72 bar below the setting of the pump s internal relief valve Following this guideline ensures the liquid does not recirculate through the intern...

Страница 9: ...4 1 Springs 25 60 psig differential range No charge option A 50 150 psig differential range No charge option B 100 225 psig differential range No charge option C O ring Material Buna N Standard A Neop...

Страница 10: ...lling pumps and aerosol propellant feed pumps T166 Used with truck pumps and multi cylinder filling pumps Part Model Standard Material Optional Material Valve body B166 T166 Ductile iron ASTM 536 60 4...

Страница 11: ...Appendix D Outline Dimensions for Model B166 All dimensions are in inches centimeters 1 438 3 7 1 750 4 4 1 375 3 5 1 375 3 5 2 105 5 3 7 926 20 1 3 4 NPT 3 4 NPT 11...

Страница 12: ...D Outline Dimensions for Model T166 All dimensions are in inches centimeters 8 3 32 20 52 1 5 16 3 33 2 7 16 6 19 1 5 16 3 33 1 5 16 3 33 1 5 16 3 33 Pipe tap options T166 1 25 1 1 4 NPT T166 1 5 1 1...

Страница 13: ...Spring seal 1 7 2 217b O ring 1 8 1138 Relief spring 25 60 psi 1 1193 Relief spring 50 150 psi 1 9 1193 Relief springs 100 225 psi 1 1313 1 10 1251 Valve 1 Ref No Part No Description Qty 11 1139 Ball...

Страница 14: ...87A Socket head 3 8 16 X 7 8 gr 8 4 6 1136 Spring seal 1 7 2 217_b O ring 1 8 1138 Spring 25 to 60 psi 1 1193 Spring 50 to 150 psi 1 9 1193 Spring 100 to 225 psi 1 1313 1 Ref No Part No Description Qt...

Страница 15: ...15...

Страница 16: ...6 CORKEN INC A Unit of IDEX Corporation 3805 N W 36th St Oklahoma City OK 73112 Phone 405 946 5576 Fax 405 948 7343 Visit our website at http www corken com or e mail us at cocsalesdept idexcorp com S...

Отзывы: