Corken B166 Скачать руководство пользователя страница 2

Warning

Install, use and maintain this equipment according to Corken’s instructions and all applicable federal, state, local laws 
and codes. Periodic inspection and maintenance is essential.

Corken One Year Warranty

CORKEN, INC. warrants that its products will be free from defects in material and workmanship for a period of one 
year from date of installation, provided that the warranty shall not extend beyond twenty-four (24) months from the date 
of shipment from CORKEN. If a warranty dispute occurs, the DISTRIBUTOR may be required to provide CORKEN 
with proof of date of sale. The minimum requirement would be a copy of the DISTRIBUTOR’S invoice to the customer.

CORKEN products which fail within the warrant period due to defects in material or workmanship will be repaired or 
replaced at CORKEN’s option, when returned, freight prepaid to CORKEN, INC., 3805 N.W. 36th St., Oklahoma City, 
Oklahoma 73112.

Parts subject to wear or abuse, such as mechanical seals, blades, piston rings, valves and packing, and other parts 
showing signs of abuse, neglect or failure to be properly maintained are not covered by this limited warranty. Also, 
equipment, parts and accessories not manufactured by CORKEN but furnished with CORKEN products are not 
covered by this limited warranty and the purchaser must look to the original manufacturer’s warranty, if any. This limited 
warranty is void if the CORKEN product has been altered or repaired without the consent of CORKEN.

All implied warranties, including any implied warranty of merchantability or fitness for a particular purpose, are 
expressly negated to the extent permitted by law and shall in no event extend beyond the expressed warrantee period.

CORKEN DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL DAMAGES DUE TO BREACH OF ANY WRITTEN OR 
IMPLIED WARRANTY ON CORKEN PRODUCTS. Transfer of toxic, dangerous, flammable or explosive substances 
using CORKEN products is at the user’s risk. Experienced, trained personnel in compliance with governmental and 
industrial safety standards should handle such substances.

Important notes relating to the European Union (EU) Machinery Directive

Pumps delivered without electric motors are not considered as machines in the EU Machinery Directive. These pumps 
will be delivered with a Declaration of Incorporation. The fabricator of the machinery must assure and declare full 
compliance with this Directive before the machine in which the pump will be incorporated, or of which it is a part, is 
put into service.

Contacting the Factory

Before you contact the factory, note the model number and serial number of your pump. The serial number directs 
us to a file containing all information on material specifications and test data applying to your specific pump. When 
ordering parts, the Corken service manual or Operations, Installation and Maintenance (IOM) manual should be 
consulted for the proper part numbers. ALWAYS INCLUDE THE MODEL NUMBER AND SERIAL NUMBER WHEN 
ORDERING PARTS.

The model and serial numbers are shown on the nameplate of the unit. Record this information for future reference.

Mod

el No. 

Serial No.
Date Purchased 
Date Installed
Purchased From 
Installed By

2

Содержание B166

Страница 1: ...f Corken products must be made only by experienced trained and qualified personnel 3 Maintenance use and installation of Corken products must comply with Corken instructions applicable laws and safety...

Страница 2: ...ties including any implied warranty of merchantability or fitness for a particular purpose are expressly negated to the extent permitted by law and shall in no event extend beyond the expressed warran...

Страница 3: ...1 Operation of the B166 External Automatic Bypass Valve 5 FEATURES OF THE T166 AUTOMATIC EXTERNAL BYPASS VALVE 7 CHAPTER 2 INSTALLATION OF THE T166 AUTOMATIC EXTERNAL BYPASS VALVE 7 2 1 Operation of...

Страница 4: ...mance of the valve Sound Levels These products are reactionary devices used in pumping systems Sound levels are highly dependent upon the application product being pumped and installation When operati...

Страница 5: ...e below For distances of 50 feet or more the next larger pipe size should be used Pipe Sizes for Discharge Line Flow Rate Pipe Size by Model Number B166B 75 B166B 1 Up to 30 GPM 3 4 Up to 40 GPM 1 1 1...

Страница 6: ...6 9 8 6 bar higher than the starting pressure EXAMPLE The starting pressure is 125 psi 8 6 bar After starting the pump it increases to 150 psi 10 3 bar and adjusts to a maximum pressure of 235 psi 16...

Страница 7: ...bypass valve is used for vapor venting the piping should be the same size used with the B166 external bypass valve To ensure optimum performance of the external bypass valve and the entire pumping sys...

Страница 8: ...external bypass valve should be set 20 25 psi 1 38 to 1 72 bar below the setting of the pump s internal relief valve Following this guideline ensures the liquid does not recirculate through the intern...

Страница 9: ...4 1 Springs 25 60 psig differential range No charge option A 50 150 psig differential range No charge option B 100 225 psig differential range No charge option C O ring Material Buna N Standard A Neop...

Страница 10: ...lling pumps and aerosol propellant feed pumps T166 Used with truck pumps and multi cylinder filling pumps Part Model Standard Material Optional Material Valve body B166 T166 Ductile iron ASTM 536 60 4...

Страница 11: ...Appendix D Outline Dimensions for Model B166 All dimensions are in inches centimeters 1 438 3 7 1 750 4 4 1 375 3 5 1 375 3 5 2 105 5 3 7 926 20 1 3 4 NPT 3 4 NPT 11...

Страница 12: ...D Outline Dimensions for Model T166 All dimensions are in inches centimeters 8 3 32 20 52 1 5 16 3 33 2 7 16 6 19 1 5 16 3 33 1 5 16 3 33 1 5 16 3 33 Pipe tap options T166 1 25 1 1 4 NPT T166 1 5 1 1...

Страница 13: ...Spring seal 1 7 2 217b O ring 1 8 1138 Relief spring 25 60 psi 1 1193 Relief spring 50 150 psi 1 9 1193 Relief springs 100 225 psi 1 1313 1 10 1251 Valve 1 Ref No Part No Description Qty 11 1139 Ball...

Страница 14: ...87A Socket head 3 8 16 X 7 8 gr 8 4 6 1136 Spring seal 1 7 2 217_b O ring 1 8 1138 Spring 25 to 60 psi 1 1193 Spring 50 to 150 psi 1 9 1193 Spring 100 to 225 psi 1 1313 1 Ref No Part No Description Qt...

Страница 15: ...15...

Страница 16: ...6 CORKEN INC A Unit of IDEX Corporation 3805 N W 36th St Oklahoma City OK 73112 Phone 405 946 5576 Fax 405 948 7343 Visit our website at http www corken com or e mail us at cocsalesdept idexcorp com S...

Отзывы: