22
Residual Heat Functions
After all cooking processes there is some heat stored in the vitroceramic
glass called residual heat. The control can calculate roughly how hot the
glass is in the worst case. If the calculated temperature is higher than + 60
° C, then this will be indicated in the corresponding heater display after the
heater or the hob control was turned off. The residual heat display is shown
as long as the calculated heater temperature is > + 60 ° C.
The display of the residual heat has the lowest priority and is overwritten
by every other display value, during safety turn offs and displaying an error
code.
After reapplying the supply voltage to the hob control after an interruption
of the supply voltage occurred, causes that the residual heat display flashes,
if the corresponding heater had a residual heat of g 60 ° C before
the power interruption occurred. The display will flash until the max. residual
heat time has expired or the heater will be selected and activated.