background image

PAGE 6

7

8

Place the second wall channel in position against the wall. 

a:

 Ensure the wall channel is vertical and mark the four holes onto the wall. 

b:

 Drill the four positions marked using a 6mm drill bit.

c:

 Apply silicone sealant to the back of the wall channels 

d:

 Insert the wall plugs. Place washers over the 32mm screws and fix the wall 

channel to the wall. If necessary, slight adjustment is available in the wall channel. 

Plan the position for the second panel, the opening can be a 
maximum of 880mm.

ø 6

mm

a

b

d

32 

mm

10

11

Carefully push the panel into the wall channel. 
Note: Wetting the edge of the panel with water will 
help the panel insert.

Attach the wall bracket assembly to the strut bracket using the 
16mm screw.

9

Slide both seals down into the wall channel and cut 
off any excess. 
Note the orientation of the soft flippers.

6

c

ø 6

mm

e

d

PN80456

38 

mm

a

1

2

b

c

f

g

Inside 

a: 

Remove the strut from the panel, place an inner wall bracket in the marked position and mark the 

fixing hole onto the wall.  

b: 

Drill the position marked using a 6mm drill bit, 30mm deep. 

c:

 Insert the wall plug and fix the inner wall bracket to the wall using a 38mm screw and washer.  

Note: The screws and wall plugs supplied are for masonry walls. For lightweight walls i.e. 
stud partitions, plasterboard etc, use the correct type of fixings.

d:

 Slide the strut bracket and wall bracket cover onto the strut. 

e: 

Reposition the strut into the inner wall bracket and the other end (with panel bracket fitted) 

onto the glass panel (with grub screws on the inside). Screw the wall bracket cover onto the 
inner wall bracket.

f: 

Tighten the wall bracket cover grub screw. 

g: 

From inside, slide the glass clamp up between the bracket and glass panel, tighten the 

grub screw (

1).

 

Ensure the panel is vertical and tighten the grub screw in the top of the panel 

bracket (

2).

 

IMPORTANT

Ensure Glass Guard H2o 
label is to the outside of 
the enclosure/panel
Satin glass patterns must 
be installed to the outside 
of the enclosure.
Note:
The Glass Guard coating is 
on the opposite side to the 
label or satin glass patterns

Max. 

opening 

880mm

PN60154

16 

mm

Содержание TUBULAR SHOWER PANELS

Страница 1: ... check very carefully that components are vertical To avoid damage use the opened out packaging to build the enclosure on EQUIPMENT NEEDED Drill 6mm Masonry Bit 3mm Metal Bit general Crosshead Screwdriver Spirit Level Pencil Fine Tooth Saw Silicone Sealant Scissors Tape Measure Note The screws and wall plugs supplied are for masonry walls For lightweight walls i e stud partitions plasterboard etc ...

Страница 2: ...ix the wall channel to the wall If necessary slight adjustment is available in the wall channel b a c 5 Assemble the strut slide on the panel bracket and wall bracket assembly Lightly tighten the fitted grub screws Carefully place the strut assembly onto the glass approximately 100mm from the edge depending on your installation Ensure the strut is level and mark the position of the wall bracket as...

Страница 3: ...onto the glass panel with grub screws on the inside Screw the wall bracket cover onto the inner wall bracket f Tighten the wall bracket cover grub screw g From inside slide the glass clamp up between the bracket and glass panel tighten the grub screw 1 Ensure the panel is vertical and tighten the grub screw Push fit the top cap onto the top of the wall channel 9 Ensure that the opening end of the ...

Страница 4: ...nsert the wall plug and fix the inner ceiling bracket to the ceiling using a 32mm screw and washer Note The opening in the inner ceiling bracket should be parallel with the end of the panel Note The screws and wall plugs supplied are for masonry walls For lightweight walls i e stud partitions plasterboard etc use the correct type of fixings 13 a Reposition the strut back onto the panel with grub s...

Страница 5: ...on Max opening 800mm c IMPORTANT Ensure Glass Guard H2o label is to the outside of the enclosure panel Satin glass patterns must be installed to the outside of the enclosure Note The Glass Guard coating is on the opposite side to the label or satin glass patterns ONLY Horizontal strut installation 4 a Ensure that the opening end of the panel is vertical and the panel is parallel with the opposite ...

Страница 6: ... the marked position and mark the fixing hole onto the wall b Drill the position marked using a 6mm drill bit 30mm deep c Insert the wall plug and fix the inner wall bracket to the wall using a 38mm screw and washer Note The screws and wall plugs supplied are for masonry walls For lightweight walls i e stud partitions plasterboard etc use the correct type of fixings d Slide the strut bracket and w...

Страница 7: ...nels Outside 12 Ensure that the end of the second panel is vertical Carefully place the second panel bracket on to the glass approximately 100mm from the edge depending on your installation Carefully measure the distance Y between the wall bracket assembly and the panel bracket Y Position the strut into the wall bracket assembly and the panel bracket Ensure the panel is vertical and tighten the gr...

Страница 8: ...tallation Ensure the strut is vertical and mark the position of the outer ceiling bracket onto the ceiling c Remove the strut assembly Drill a hole in the centre of the position marked using a 6mm drill bit 30mm deep d Insert the wall plug and fix the inner ceiling bracket to the ceiling using a 32mm screw and washer Note The opening in the inner ceiling bracket should be parallel with the end of ...

Страница 9: ...ntact your local authority to find your nearest recycling centre 22 Place the second wall channel in position against the wall a Ensure the wall channel is vertical and mark the four holes onto the wall b Drill the four positions marked using a 6mm drill bit c Apply silicone sealant to the back of the wall channels d Insert the wall plugs Place washers over the 32mm screws and fix the wall channel...

Отзывы: