![CopperOptics 150-1365-04 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/copperoptics/150-1365-04/150-1365-04_manual_2666209029.webp)
363-765-104-04
February 19, 1998
Revision
04
FRE-765
List
4x
PairGain
Engineering - Plant Series
25
For the List 4D and List 4E FRE-765 enclosures, splice the subscriber connections to the cable stub per
*
For the FRE-765 List 4D and 4E RT Enclosure, the cable on the rear of the protection
block subassembly is installed in connector P1 on the RT enclosure backplane.
†
Shaded terminations used only with the 8 Channel POTS or 4 Channel DDS Units.
Table 16.
Subscriber Terminations for Lists 4D and 4E
*
†
Channel
Unit
Circuit
25-Pair Subscriber Cable
Stub
Protector
Tip
Ring
Strip
Socket
1
WH
BL
PB1
1
2
WH
OR
PB1
2
3
WH
GN
PB1
3
1
4
WH
BN
PB1
4
5
WH
SL
PB1
5
6
RD
BL
PB1
6
7
RD
OR
PB1
7
8
RD
GN
PB1
8
1
RD
BN
PB1
9
2
RD
SL
PB1
10
3
BK
BL
PB2
1
2
4
BK
OR
PB2
2
5
BK
GN
PB2
3
6
BK
BN
PB2
4
7
BK
SL
PB2
5
8
YL
BL
PB2
6
1
YL
OR
PB2
7
2
YL
GN
PB2
8
3
YL
BN
PB2
9
3
4
YL
SL
PB2
10
5
VI
BL
PB3
1
6
VI
OR
PB3
2
7
VI
GN
PB3
3
8
VI
BN
PB3
4