Revision
04
February 19, 1998
363-765-104-04
8
PairGain
Engineering - Plant Series
FRE-765
List
4x
FUNCTIONAL DESCRIPTION
Operational Capabilities
The FRE-765 List 4x RT enclosure requires the following plug-in units:
•
one RT Line Unit which is line powered via the HDSL pairs that connect the RT to the PG-Flex COT line
units installed in a COT Shelf.
•
one Channel Unit, minimum, with a maximum installation of three Channel Units, supporting up to 24
channels.
shows how circuit assignments are configured in the FRE-765 with the following deployment rules:
•
for channel units providing four (4) circuits, Ckt 1 through Ckt 4 are used for Tip and Ring terminations.
•
for channel units providing eight (8) circuits, Ckt 1 through Ckt 8 are used for Tip and Ring terminations.
•
for a 24-channel system, you can provision a maximum of 24 circuits.
Each PG-Flex channel unit provides four (4) or eight (8) circuits.
shows how the channels are assigned,
dependent on the type of service provided, such as:
•
Plain Old Telephone Service (POTS)
•
Integrated Services Digital Network (ISDN)
•
Digital Data System (DDS).
Table 2.
FRE-765 Circuit Assignments
Line Unit
Channel Unit 1
Channel Unit 2
Channel Unit 3
Channel Unit 4
Refer to
and
for Line Unit
Terminations
from the Backplane
Ckt 1
Ckt 1
Ckt 1
Ckt 2
Ckt 2
Ckt 2
Ckt 3
Ckt 3
Ckt 3
Ckt 4
Ckt 4
Ckt 4
Not
Ckt 5
Ckt 5
Ckt 5
Used
Ckt 6
Ckt 6
Ckt 6
Ckt 7
Ckt 7
Ckt 7
Ckt 8
Ckt 8
Ckt 8