Section 150-612-100
Revision 02
Page 8
RLBO
0
*: Configures the T1 RCV LBO to 0 dB. This sets
the T1 output signal level from the HRU towards the
NI to 0 dB. This setting is recommended when the
HRU does not function as the NID but is connected
to en external NID. It allows the external NID to set
the appropriate NI level.
15
: Configures the T1 RCV LBO to -15 dB. This sets
the T1 output signal level from the HRU towards the
NI level to -15 dB. This setting is recommended
when the HRU functions as the NID.
Note that the “ * “ denotes the factory setting.
Figure 5. HRU-612 Loopbacks.