COPA Eon Wall Hung Boiler User’s and Installation Manual
25
1.6. Usage of the Wall Hung
Boiler
Before starting to use the product,
the installation should be filled
until the water pressure reaches
1.5 bar
The water pressure system in the
product works between 0.5 bar
and 3.0 bar. If the water pressure is
below 0.5 bar, the product does
not work and gives a warning on
the display. If the water pressure is
above 3.0 bar, there is a partial
water discharge from the safety
valve of the product. This situation
is not a water outlet failure and it
stops when the water pressure
drops below 3.0 bar. The water
pressure can be seen both on the
display and on the pressure gauge
under the product.
Figure 1.6.2
Usage of the Product
and Interfaces
Figure 1.6.3
Wall Hung Boiler Interface
Control key group
1
LCD display
2
Temperature adjustment
3
1
1
5
2
3
4
6
2
Mode
Domestic Hot Water Temperature
Radiator Temperature
Eco/Reset
3
4
5
6
LCD display
Temperature Adjustment
1
2
3
•
•
1
2
3
4
0
Figure 1.6.1
Water Filling