COPA Eon Wall Hung Boiler User’s and Installation Manual
1.1. General Warnings
20
• The product must be connected
to an installation with earthing
in compliance with regulations.
• The power of the product must
be shut off before
commissioning or servicing.
• The selection of the piping and
the radiators must be done
according to the rules specified
in the relevant regulations.
• The gas connection of the
product must be made with the
approval of the relevant gas
company.
• Problems arising in the product
due to the electrical system are
not the responsibility of the
manufacturer.
• Before commissioning the
product: Check that there are
filters in the system and
domestic water inlets, valves in
the inlet and outlet of the
installation and the tap water
inlet and that the installation is
clean and ready for use.
• Only antifreeze approved by
COPA authorized services must
be used.
• Before commissioning the
product, it must be ensured that
there is no water leakage in the
entire installation.
• Domestic water must be at
maximum 8 bar pressure and
20° French Hardness (1° F = 10
ppm CaCO3). If it is harder than
20°
French Hardness (1° F = 10 ppm
CaCO3), it is mandatory to use
demineralized or suitable water
in order to prevent scaling in
the boiler caused by hard water.
COPA is not responsible for any
damage caused by water over
20° French Hardness. If the city
network water pressure is
higher than 6.5 bar, a pressure
reducer must be installed.
• It must be ensured that the wall
to which the product will be
hung has sufficient strength.
Steel reinforcement must be
used, if necessary.
• 3x1.5 mm² NYAF cable and 2 A
V-type circuit breaker must be
used for the electrical
connection.
• The product is designed suitable
for 195-255 V, 50 Hz AC power
supply. For the parameters of
other than these values, a
power regulator must be used.
• The ambient temperature where
the product is located must be
between -10˚C and 50˚C. The
product should not be powered
off in order to prevent freezing.
• This product has been manufac
tured according to the relevant
AEEE and Rohs directives.
Polychlorobiphenyl (PCB) and
similar chemicals were not used
in the product.
• Even if the product is within the
warranty period, the product is
out of warranty in case
malfunctions and damages
occur because of the violation
of the warnings in the manual.
Содержание eon
Страница 1: ...eon Kullanım ve Montaj Kılavuzu copa com tr ...
Страница 20: ...eon User s and Installation Manual copa com tr ...
Страница 39: ...eon Руководство по эксплуатации и монтажу copa com tr ...
Страница 58: ...eon 使用及安装说明书 copa com tr ...
Страница 77: ......
Страница 79: ......
Страница 80: ...M ü ş t e r i H i z m e t l e r i ...