COPA Eon Wall Hung Boiler User’s and Installation Manual
1.3. Flue Connections
• The product is a C2 type fan
supported hermetic device. If it
is to be connected to the flue
system as of B2 type, the
environment should be
suitable for the ventilation
system shown in Figure 1.3.1.
The environment should have
a minimum volume of 1 m³ per
kW capacity.
• An 800 mm long telescopic pipe
is supplied with the product as
standard. However, flue
connections specified in
Figures
1.3.2, 1.3.3 and 1.3.4
can also
be applied. The lengths
specified in
Figures 1.3.2, 1.3.3
and 1.3.4
are the lengths given
without deducting the losses.
For the net values, please refer
to the equivalent loss table
given below
22
Figure 1.3.1
The Environment for B2
Type Connection
Maximum Equivalent
Flue Length 4 m
Figure 1.3.2
Maximum Equivalent
Flue Length 12 m
Figure 1.3.3
(Coaxial 60/100 Ø)
(Coaxial 80 Ø)
Coaxial 60/100
4 m
1 m
0.5 m
Coaxial 80/125
20 m
0.5 m
0.25 m
Allowable maximum length
Reduction factor for 90° elbow
Reduction factor for 45° elbow
M equivalent loss table for coaxial flues
Losses in m equiv.
Equivalent loss table for coaxial flues m equivalent
EON
Allowable maximum length
60 m equiv.
Maximum m equivalent lengths for separate flues
Air Suction
Fume Discharge
Vertical Horizontal
Ø 80
ELBOW
PIPE
1 m
45°
90°
90°
Test outlet
1,2
1,5
1,5
1,8
2
2
1
1,6
2
Содержание eon
Страница 1: ...eon Kullanım ve Montaj Kılavuzu copa com tr ...
Страница 20: ...eon User s and Installation Manual copa com tr ...
Страница 39: ...eon Руководство по эксплуатации и монтажу copa com tr ...
Страница 58: ...eon 使用及安装说明书 copa com tr ...
Страница 77: ......
Страница 79: ......
Страница 80: ...M ü ş t e r i H i z m e t l e r i ...