NVR User Manual
29
for schedule for alarm out are similar to normal schedule setup (see Chapter 5.4.1 for details).
This step is very important for alarm out. Even if you have enabled alarm out in the motion
based alarm or sensor based alarm, you will not see the result of alarm out if no schedule is
added here.
To set up buzzer:
Step 1
: Enter into Menu
Setup
Alarm Out
Buzzer.
Step 2
: Checkmark Buzzer and set buzzer alarm hold time. This would trigger the buzzer
when the system is on an alarm.
5.6 Network Configuration
Network configuration includes four submenus: network, Email, server and other settings.
Network settings must be configured if NVR is used for monitoring over network.
5.6.1 Network
To set up network:
Step 1
: Enter into Menu
Setup
Network
Network tab. Refer to Fig 5-23:
Fig 5-23 Network Configuration-Network
Step 2
: Set HTTP port. The default HTTP port is 80. If the value is changed, you shall add the
port number when typing IP address in IE address blank. e.g. If HTTP port is set to 82 and IP
address is http://192.168.0.25
,
you should input the following IP address:
http://192.168.0.25:82 into IE browser.
Step 3
: Set server port. The default server port is 6036.
Step 4
: Connect internet. There are three ways to connect internet.
If you have a DHCP server running and would like your NVR to automatically obtain an
IP address and other network settings, check the checkbox beside "Obtain an IP address
automatically". Then the device will distribute IP address, subnet mask, and gateway IP
and DNS server.
If you want to configure your own settings, disable “Obtain an IP address automatically”
item and input the IP address, subnet mask, gateway IP and DNS server.