KEY-KP01

Installation

Siting the Keypad

Do site the keypad:

  Within the area protected by the alarm system.

  At a convenient height and location for the user.

  Out of sight of potential intruders.
Do NOT site the keypad:

  Next to electronic equipment, particularly computers, photocopiers or other 

radio equipment, CAT 5 data lines or industrial mains equipment.

  Where the cable run from the end station will be longer than 100m 

to an i-on16, 250m to an i-on40 or 1,000m to an i-on50EX/160EX/

Menvier30/40/100/300.

Note: Do not site two or more keypads, or a keypad and an external prox 

reader, closer than one metre together. Otherwise their prox readers will inter-

fere and be unable to read tags. For the same reason do not place the keypad 

or external prox reader less that one metre from any other type of proximity 

tag reader, for example those used in access control systems.

Fitting

Use 4mm x 25mm countersunk screws with a thread suitable for the wall ma-

terial. Fit in at least three fixing holes when mounting the back of the keypad 

on the wall. (See Figure 4.) A screw is supplied for the tamper block.
Cooper Security recommend that you mount the keypad as follows:
1. Select which cable entry you are going to use and break out the appropriate 

plastic sections.

2. For Security Grade 3 installations:

a) Hold the backplate in place against the wall and mark the position of the 

hole in the tamper block (see Figure 3).

b) Drill and plug the hole, and screw the backplate to the wall through the 

tamper block using the supplied screw. Do not tighten the screw com-

pletely home.

3. Make sure the backplate is level and mark, drill and plug at least three other 

fixing holes. Screw the backplate to the wall through the fixing holes using 

the M4 screws.

4. For Security Grade 3 installations cut the plastic webs connecting the 

tamper block to the remainder of the baseplate.

Note: If you do not cut the webs then the tamper switch will not operate if the 

complete keypad is forced off the wall. The keypad will not comply with Grade 

3 requirements.

5. Mount the front of the keypad (containing the keypad pcb) onto the back-

plate and make sure that the tamper switch operates.

Connect Keypad to End Station

CAUTION: Remove all power (both mains and battery) from the control unit 

before connecting the keypad. Figure 7 shows connection details.

Содержание key-kp01

Страница 1: ...A B C D 1 4 ghi 7 pqrs 0 2 abc 5 jkl 3 def 6 mno 8 tuv 9 wxyz key kp01 Installation Guide Issue 1 ...

Страница 2: ... pqrs 0 2 abc 5 jkl 3 def 6 mno 8 tuv 9 wxyz 2 3 6 5 5 4 7 1 Fig 1 Fig 2 1 LCD display 2 Programming keys 3 Navigation keys This key has built in alert LEDs To disable the LEDs see page 11 4 Setting and unsetting keys The ABCD keys have built in status LEDs that can show the setting status of a part setting system These LEDs can be disabled see page 11 5 Lid screws under plastic caps 6 Hold Up Ala...

Страница 3: ...le entry 4 Tamper block 2 3 4 BRIGHT TERM 0V 12V A B 0V 12V D0 D1 LED EXT READER RS485 1 6a 6b 3 4 5 6 2 Fig 5 1 Tamper switch 2 Sounder 3 Connector for KEY EP 4 Sounder volume control 5 Connector for data bus 6 Jumpers for 6a Addressing 6b LED functions and RS485 bus termination ...

Страница 4: ...40 Kpd 2 Kpd 1 Kpd 3 Kpd 4 Fig 6 RS485 0V 12V A B OP CONTROL UNIT 0V 12V A B Fig 7 2 3 4 1 Fig 9 Fig 8 1 1 2 3 1 LED window 2 Retaining Screw 3 Removable Fixing Plate 4 Permanently attached cable 1 Fixing hole 2 Cable entry 3 Anchor for retaining screw ...

Страница 5: ...Page 5 KEY KP01 Fig 10 Fig 11 12V 0V D0 D1 LED EXT READER BLUE LED WHITE D1 GREEN D0 BLACK 0V RED 12V External Prox Reader KEY KP01 Note Do not connect yellow wire ...

Страница 6: ...10 KEY EP External Prox Reader 10 Siting the External Prox Reader 10 Opening the External Prox Reader 10 Fit External Prox Reader 10 External Prox Reader Connection 11 Maintenance 11 Testing the Keys 11 Cleaning 11 Programming 11 Backlight ABCD LEDs and Navigation Key LEDs 11 Entering Local Programming Mode 11 To Switch ABCD LEDs ON or OFF 12 To Change Backlight Settings 12 To Disable Enable the S...

Страница 7: ...erneath see Figure 2 Gently swing the lower side of the front out from the back box by about 10mm and then slide the front upwards to disengage the top catches Be careful not to pull the lower side of the front more than about 25mm away from the back while the top catches are engaged or you may break the catches Figure 3 shows the cable entries and fixing holes in the back box The front plastic ho...

Страница 8: ... A screw is supplied for the tamper block Cooper Security recommend that you mount the keypad as follows 1 Select which cable entry you are going to use and break out the appropriate plastic sections 2 For Security Grade 3 installations a Hold the backplate in place against the wall and mark the position of the hole in the tamper block see Figure 3 b Drill and plug the hole and screw the backplate...

Страница 9: ...sta tion connector For a parallel connection the cable length should not exceed 100m For serial connection the cable length from to the most distant keypad should not exceed 100m for an i on16 250m for an i on40 or 1 000m for an i on50EX 160EX or Menvier30 40 100 300 Keypad Connection See Figure 7 for wiring connections at the keypad and control unit Bus Termination at the Keypad See the relevant ...

Страница 10: ...er than one metre to any other kind of prox reader for example the i kp01 or another external prox reader If you do so then the prox readers will interfere and be unable to read tags Opening the External Prox Reader To open the external prox reader see Figure 10 1 Undo the single retaining screw 2 Tilt the edge of the fixing plate and then slide a short distance parallel to the body of the prox re...

Страница 11: ...disable the backlights set the function of the LEDs on the ABCD keys or disable enable the LEDs under the navigation key by entering a local keypad programming mode this replaces the use of jumpers on the keypad PCB i onEX and Men vier30 40 100 300 control units can change the keypad backlighting from the installer Menu do not use the keypad s local programming mode It is possible to enter keypad ...

Страница 12: ...GHT Y Backlight timed X The backlight will glow for 10 seconds after the last keypress The action of the backlight depends on the programming of the control unit which must have Release 4 03 software installed MENU BACKLIGHT X 4 Leave local programming mode and save your changes see page 13 To Disable Enable the Status OK LED Action Keypad Display 1 Enter Local Programming mode see page 11 MENU AB...

Страница 13: ...EITHER Press Y OR Close the keypad tamper The keypad saves the changes you have made in its local memory You can now remove 12VDC power if required or leave Installer Menu on the control unit To Leave Local Programming Mode and Discard Changes Press X The keypad ignores any changes you have made External Prox Reader LED The KEY EP has a built in LED that can glow for 10s to indicate that the syste...

Страница 14: ...Page 14 KEY KP01 Notes ...

Страница 15: ...Page 15 KEY KP01 Notes ...

Страница 16: ...RCHASE PRICE OF THE PRODUCT FROM WHICH THE CLAIM ARISES TO THE EXTENT PERMITTED BY APPLICABLE LAW THESE LIMITATIONS AND EXCLUSIONS WILL APPLY WHETHER COOPER S LIABILITY ARISES FROM BREACH OF CONTRACT BREACH OF WARRANTY TORT INCLUDING BUT NOT LIMITED TO NEGLIGENCE STRICT LIABILITY BY OPERATION OF LAW OR OTHERWISE Every effort has been made to ensure that the contents of this book are correct The co...

Отзывы: