General Doppler Care and Service

1)  The transducer crystal area should be wiped clean with a tissue after each
use. Alcohol may be used if desired. Although MedaSonics does not recom-
mend or endorse any specific disinfecting agent to be used with MedaSonics
devices, many disinfecting products are commercially available. These prod-
ucts may be purchased at any local drug store. Do not autoclave the unit or
sterilize with Sterrad

®

or Steris

®

systems. Do not immerse the unit in liquid.

Avoid dropping it.

2)  If the Doppler will be stored for a long time, the battery should be removed.

3)  MedaSonics, Inc. maintains a service facility which has the capability to
promptly repair all products returned to the factory.

Due to the advanced technology that has made this product possible, there are no
user-serviceable parts inside the control unit or Doppler. Special equipment is
required for servicing this product, and can only be performed by your service
agent. For service, contact MedaSonics Service Department at (800)-227-8076 or
(203)-929-6321. Prepaid, insured shipment for factory service should be sent to:

Service Manager
CooperSurgical Inc.
15 Forest Parkway
Shelton, CT 06484

Battery Replacement

1)  Press and lift the cover of the battery compartment, lift out used battery.
2)  Insert new battery, ensuring polarity of battery corresponds with battery clip.
3)  Slide the battery cover back into position.

Return Policy

A Return Material Authorization (RMA) number must be obtained before return-
ing any product. The product must be in new condition in the original packag-
ing, and shipped to MedaSonics prepaid with tracer capability.  Restocking fees
are based on the following schedule:

- 14 -

- 13 -

Time in the field

Restock Fee

0 to 2 weeks

0%

2 to 4 weeks

25%

4 to 8 weeks

50%

>8 weeks

100%

Items returned without proper authorization are subject to a 50% Restock Fee.
Time in the field is based on the Ship Date of the equipment and the date the
unit is received back at MedaSonics—not the date the RMA is issued.

Содержание Medasonics TRIA P338

Страница 1: ...General Doppler Cautions and Considerations 12 General Doppler Care and Service 13 Battery Replacement 13 Return Policy 13 Warranty 15 Specifications 16 Ultrasonic Output 17 Definition of Terms 18 Tr...

Страница 2: ...Display and 2 MHz Fetal 5 MHz Vascular Probes T345 TRIA Fetal Doppler 2 MHz T346 TRIA Vascular Doppler 5 MHz T336 TRIA Doppler Waterproof Fetal Probe 2 MHz P338 TRIA 2 MHz Fetal Probe P339 TRIA 5 MHz...

Страница 3: ...al heart rate display and one or more Doppler probe s that contain the ultrasound transducer and Doppler electronics Choice of a probe depends on the clinical application The MedaSonics Tria 2 MHz Fet...

Страница 4: ...e level on the Doppler This increases the audio signal upon which the algorithm can operate and will allow it to lock on to the signal and accurately display the heart rate Standard Fetal Probe The 1...

Страница 5: ...ed for proper coupling during underwater use 3 Ensure that the speaker unit and Doppler probe are securely connected through the cord Holding the Doppler probe place the tip on the site to be examined...

Страница 6: ...he end of the connector with the notch on the end of the wand and push gently until they snap together 10 9 Note The probe on the dedicated vascular Tria System is permanently wired to the speaker uni...

Страница 7: ...e before and after such procedures 7 Useful in emergency medicine and noisy environments to take blood pres sure pulse rates and to evaluate suspected arterial injuries 8 Urological applications inclu...

Страница 8: ...s product and can only be performed by your service agent For service contact MedaSonics Service Department at 800 227 8076 or 203 929 6321 Prepaid insured shipment for factory service should be sent...

Страница 9: ...d to weather theft or abuse This warranty does not apply to batteries shipping case or other accessories or to damage from shipping tampering misuse or negligence Preventative maintenance the refinish...

Страница 10: ...e location of the axial spatial peak in cm 18 17 Definition of Terms Ultrasonic Output Tables Note The uncertainty in these measurements was calculated per NEMA UD 2 Appendix A to be 24 ISPTA0 3 The d...

Страница 11: ...e and speaker unit Volume control set Turn up volume too low On LED does not light Battery dead Replace battery when switched on If the problem persists after trying the above suggestions please conta...

Страница 12: ...1...

Страница 13: ...MEDASONICS User s Manual 15 Forest Parkway Shelton CT 06484 800 227 8076 203 929 6321 fax 203 926 9435 www coopersurgical com Part 054 0223 010 Rev C 10 01 Handheld Doppler...

Отзывы: