background image

O ACCESSORIES

[Order Separately]

MOUNTING CONFIGURATIONS

Wall Mount

Arm Mount Single

EPA: 1.62

Arm Mount 2 @ 180°

EPA: 3.24

Arm Mount 2 @ 90°

EPA: 3.24

Arm Mount 3 @ 120°

(Round Pole Only)

EPA: 4.43

Arm Mount 4 @ 90°

EPA: 5.03

Arm Mount 3 @ 90°

EPA: 4.43

DRILLING PATTERNS

Type “M”

Wall Mount 

Trunnion Mount

3/4" [20mm]
dia. hole

(2) 5/8" [16mm]
dia. holes 

4 7/8" [124mm]

2 7/16" [124mm]

2 5/16"

[59mm]

12"

[305mm]

4 7/8"

[124mm]

9/16" [14mm]

Dia. Hole (4)

6 1/2"

[165mm]

8"

[203mm]

10 1/2"

[267mm]

ELECTRICAL POWER TRAY

[PT] 

Electrical componentry mounted 
to an optional swing-down 
galvanized steel power tray with 
integral handle. Electrical 
disconnects allow tray to be 
completely removed from housing 
providing ample hand and tool
room during fixture maintenance
and installation.

EXTERNAL HOUSE SIDE SHIELD

[MA1221] 
External house side shield designed
to provide sharp cutoff behind pole
while shielding the lamp from 
direct view. Mounted to the door
via four (4) stainless steel fasteners,
the MA1221 external house side
shield provides industry leading
glare and spill light control.

VANDAL SHIELD

[TR/VS] 

Door mounted 3/16" thick 
polycarbonate shield prevents lens
damage from particulates and 
projectiles. Treated with a UV 
inhibitor to discourage the gradual
discoloration that results from 
exposure to UV emitting sources.

PREMIUM SEGMENTED OPTICS

Five (5) optional high efficiency 
segmented optical systems 
constructed of premium 95% 
reflective anodized aluminum
sheet. Optical segments are rigidly
mounted inside a thick gauge 
aluminum housing for superior 
protection. All segment faces are
clean of rivet heads, tabs or other
means of attachment which may
cause streaking in the light 
distribution.

QUARTZ RESTRIKE

[Q, EM]

Optional quartz restrike [Q] 
energizes auxiliary quartz lamp
upon power reactivation and 
extinguishes once HID lamp 
re-ignites. Quartz restrike 
with time delay [EM] adds 
cold start activation.

NEMA TWISTLOCK
PHOTOCONTROL RECEPTACLE 

[4]

Gasketed photocontrol receptacle for
mounting a standard NEMA 
photocontrol (order separately). 
Button-style photocontrol [P] also
available.

INTERNAL MAST ARM MOUNT

[S]

Optional internal mast arm mount

accepts a 1 1/4" to 2 3/8" O.D. 

horizontal tenon while 4-bolt 

clamping mechanism secures 

fixture. Cast-in leveling guides 

provide ±5° vertical leveling 

adjustment.

ADJUSTABLE SLIPFITTER 

[OA1090]

Optional knuckle mount with 
internal wireway enables vertical 
tilt adjustment. Knuckle slip fits over
vertical 2 3/8" O.D tenon and is 
secured by two (2) 1/2" bolts. 

3" [77mm]

1 1/2"

[39mm]

13/32" 

[11mm]

slot

1"

[25mm]

7/16" [12mm] 
x 3/4" [20mm]

slot (2) 

Содержание Tribute

Страница 1: ...Tribute Area Luminaire ...

Страница 2: ...ull cutoff Whether selecting a high efficiency hydroformed optic or a premium 95 reflective segmented reflector Tribute s optical versatility provides custom tailored lighting solutions for exacting site requirements Tribute also features Cooper s exclusive SLE Spill Light Eliminator optic which provides outstanding cutoff behind the pole and maximum street side reach MOUNTING VERSATILITY Tribute ...

Страница 3: ......

Страница 4: ...e cast housing for optimal heat transfer and operating efficiency Optional swing down galvanized steel power tray with integral handle and quick disconnects allows tray to be completely removed from housing providing ample room for fixture installation and maintenance MOUNTING Extruded 8 aluminum arm features internal bolt guides for easy positioning of fixture during installation to pole or wall ...

Страница 5: ...ated with a UV inhibitor to discourage the gradual discoloration that results from exposure to UV emitting sources PREMIUM SEGMENTED OPTICS Five 5 optional high efficiency segmented optical systems constructed of premium 95 reflective anodized aluminum sheet Optical segments are rigidly mounted inside a thick gauge aluminum housing for superior protection All segment faces are clean of rivet heads...

Страница 6: ...eight Mounting Footcandle Values for Height Isofootcandle Lines A B C D E TRU40SXX3F TRU40SXX4F 20 3 00 1 50 0 75 0 30 0 15 25 2 00 1 00 0 50 0 20 0 10 30 1 38 0 69 0 34 0 13 0 06 TRU40MXX3S 400 Watt MH 40 000 Lumen Clear Lamp Type III Segmented TRU40MXX4S 400 Watt MH 40 000 Lumen Clear Lamp Type IV Segmented TRU40SXX4F 400 Watt HPS 50 000 Lumen Clear Lamp Type IV Formed TRU40MXX3F 400 Watt MH 40 ...

Страница 7: ...nal House Side Shield Kit for 4F OA RA1016 Photoelectric Control 105 285V NEMA Type OA RA1027 Photoelectric Control 480V NEMA Type OA RA1201 Photoelectric Control 347V NEMA Type OA RA1013 Shorting Cap MA1010 XX Single Tenon Adapter for 3 1 2 O D Tenon MA1011 XX 2 180 Tenon Adapter for 3 1 2 O D Tenon MA1012 XX 3 120 Tenon Adapter for 3 1 2 O D Tenon MA1013 XX 4 90 Tenon Adapter for 3 1 2 O D Tenon...

Страница 8: ...Portfolio Iris Shaper io Lumière Invue McGraw Edison Streetworks Fail Safe MWS DLS RSA Ametrix Printed in USA ADW071181 Domestic Facilities Cranbury New Jersey Elk Grove Village Illinois Irving Texas Ontario California Peachtree City Georgia Canadian Facilities Calgary Alberta T2E 7V9 Chomedey Laval P Q Cooper Industries Ltd 600 Travis Ste 5800 Houston TX 77002 1001 P 713 209 8400 www cooperindust...