4
Installation Instructions for the AUX Universal Edge Lit Exit
TROUBLE SHOOTING HINTS:
If LED display or charge indicator LED does not illuminate, check the following:
SCHEMATIC:
Voltages and wire colors may vary for international versions. Check wire tags.
W7
PS1
W8
JK1
c
CN1
LED11
LED1
LED2
LED3
LED4
LED5
LED6
LED7
LED9
LED10
LED8
+
041-1389
c
W8+ W7
W9 VC
C
RMT-
RMT+
REMOTE
SW
RL
GL
LED_Out
GND
LED_In
W`
O
B
JP5
JP7
C1
0
C1
1
JP1
JP6
CN3
CN4
FAI
+
C8
+
C7
+
C1
2
CN1
L1
J1
FLASHER
CN2 ICSP
JP2
MO
V1
MO
V2
F1
JP3 JP4
C1
CHARGER/DRIVER PCB
LED PCB
WHITE LEAD - TO NEUTRAL
BLACK LEAD - TO 120V
ORANGE LEAD - TO 277V
BATTERY
PULL JUMPER LABELED “FLASHER” TO ENABLE
SIGN FLASHING IN EMERGENCY MODE
1. Check AC supply – verify that unit has 24 hour AC supply.
2. Unit is shorted.
3. If following the abo ve trouble shooting hints does not solve your problem, contact your