6
7. CLEANING AND MAINTENANCE OF THE UNIT
NOTE:
In order to improve the performance of the humidifying
device, you must use warm water, but not above 30°C.
Salt deposits on the discs also helps improve the
humidifying capacity, because salt create additional
micro-structure of the disc surface, contributing to
greater wettability.
The higher the temperature of the air, the faster
humidification.
www.cooperandhunter.com
Cleaning of tub and cleaning drum
The regular cleaning of the tub and the cleaning drum (every 2 weeks)
ensures the faultless, hygienic operation of CH-PH2240W.
1. Switch the device off and disconnect the power plug.
2. Lift the housing cover (1.1) from the device. Pull the water tank up to
remove it from the housing (1.2).
3. Pull the tub out of the housing and remove the cleaning drum (3.1).
4. Clean the tub and the cleaning drum with warm water and a soft cloth.
5. Insert the cleaning drum back into the tub and then push the tub into
the housing.
Cleaning the housing
Clean the housing of CH-PH2240W with a slightly damp cloth.
NOTE:
Use a solution of 50:50 vinegar and water or a 3:1
solution of vinegar essence and water. Do not use
abrasive or corrosive cleaners.
Replacing the filter
The combination filter should be replaced after 1000 operating hours.
“CL” will automatically flash on the display after 1000 operating hours.
Use only original C&H filters!
Proceed as follows to change the filter:
1. Switch the device off and disconnect the power plug.
2. Remove the filter cover on the side of the device (2.1) and remove the
filter (2.2).
3. Remove the packaging from the new filter and place the new filter into
the filter cover (2.2). Ensure that the white side of the filter faces in
(towards the device).
4. Place the filter cover back into the device. Ensure that the filter unit is
correctly inserted.
5. Reconnect the power cord to a power outlet and switch the device on.
6. Push and hold key (
M
) for 5 seconds. A signal sounds and the „CL”
symbol disappears. The operating time meter is
now reset.
Cleaning the filter
Regular cleaning of the combination filter (1x month) ensures faultless
operation of the CH-PH2240W.
1. Switch the device off prior to cleaning and
disconnect the power plug.
2. Remove the filter cover on the side of the device (2.1).
3. Remove the filter from the cover (2.2) Use the brush attachment of a
vacuum cleaner to thoroughly clean the filter. The filter cannot be washed!
4. Insert the filter back into the filter cover (2.2). Ensure that the black side
of the filter faces out. Insert the filter cover back into the device. Ensure
that the filter unit is inserted correctly.
•
Switching on and off.
A red symbol appears on the display if there is no water in the tank
and the device shuts off automatically. Fill the water tank as
described in Chapter ”