Heat Pump
Unitherm 3 R32
18
(2)
CH
-H
P8.0SIRK
Description:
Unit: inch
No.
Name
Remarks
1
Liquid-side Service Valve
1/4
CH
-H
P6.0SIRK
CH
-H
P8.0SIRK
CH
-H
P6.0SIRK
2
Gas-side Service Valve
1/2
3
Handle
Used to cover or uncover the front casew
4
Air discharge Grill
/
6.2.3 Space requirements for installation
Wall
Wall
Wall
>
200
>
200
>
300
>
350
>
1000
>
1000
>
250
Wall
6.2.4 Precautions on installation of outdoor unit
(1) When moving outdoor unit, it is necessary to adopt 2 pieces of long enough rope to hand the unit from
4 directions. Included angle between the rope when hanging and moving must be 40
℃
below to prevent
center of the unit from moving.
(2) Adopt M12 bolts components to tighten feet and under frame when installing.
(3) Outdoor unit should be installed on concrete base that is 10cm height.
(4) Requirements on installation space dimension of unit’s bodies are shown in following drawing.
(5) Outdoor unit must be lifted by using designated lifting hole. Take care to protect the unit during lift. To avoid
rusting, do not knock the metal parts.
(6) Note that when release and refix the screw of the clasper, your hand should support the panal.And
then,after connected power cable,please ensure using the elastic trip of accessory to tighten with the pipe.