background image

4

w w w . c o o l a z o n e . c o m

Installation & Set-Up

INSTALLATION:

If the fan is placed close to a wall or other obstacle, keep a distance of 3 feet between the 

wall or obstacle and the face of the cooling pads. 

When placing the fan, take the following into consideration: 

 

a.  Uninterrupted fresh air should be made available to the cooling pad side of the unit. 

Please do not use the fan in a closed area. 

b.  Avoid blocking the air output (front) side of the fan. Cool air released from the unit 

should be able to freely circulate within an open area. 

c.  In order to prevent air from being re-circulated, ensure that the area to be cooled is 

properly ventilated.

If you have placed the unit at a location where it is inconvenient to connect the water inlet 

to a water source, you may pour clean water into the back of the unit. 

A full sump tank supply the necessary water for about 3 hours.

Water Valve

Drain Line

Water Inlet

Electric Cord

Rear / Cooling Pad Side

Front / Fan Side

Содержание C200

Страница 1: ...User Manual C400 C300 C200 9052 Long Point Houston TX 77055 888 827 1675 info coolazone com www coolazone com ...

Страница 2: ...e 11 Specifications Page 12 Applications Page 13 CE Certificate Page 14 Contact Information Page 15 Product Registration Page 16 Table of Contents Transportation Installation Set Up Operating Procedures Storage Care Cleaning Safety Parts Specifications Applications CE Certificate Contact Information Product Registration 2 www coolazone com ...

Страница 3: ...he fan is being transported avoid any impact or collision or applying excessive weight to the unit Excessive weight could damage the unit under these circumstances 3 www coolazone com Moving State Fixed State Unlocked Caster Locked Caster ...

Страница 4: ...a closed area b Avoid blocking the air output front side of the fan Cool air released from the unit should be able to freely circulate within an open area c In order to prevent air from being re circulated ensure that the area to be cooled is properly ventilated If you have placed the unit at a location where it is inconvenient to connect the water inlet to a water source you may pour clean water ...

Страница 5: ...to make any water flow adjustments When proper adjustments are made a slow drip should be enough water to keep the pads soaked Note that excessive water flow can reduce efficiency in air cooling With proper adjustment cooling capacity will be increased New pads in the unit require a breaking in period for up to one week before optimal efficiency can be achieved Front Fan Side Water Valve SPRAY BAR...

Страница 6: ... 1 hour of operating time After the set operating time has expired the unit goes into auto shut down mode whereby the water pump shuts down a 15 minute timer is activated and the fan continues to blow to dry the cooling pads When the 15 minute timer is complete the unit powers down For example if 4 hours of operating time is required only 3 hours and 45 minutes is needed when setting the timer Aft...

Страница 7: ...f First shut off the pump then the fan To turn the pump on or off push the PUMP ON OFF button To turn the fan or off push the FAN ON OFF button Turn off the power switch once the pump and motor have stopped After starting the automatic operation system if there is a need to switch the pump or fan on off press the pump or fan on off button on the Manual Control Panel To turn the pump or fan on off ...

Страница 8: ...er level in the tank is too low to circulate in the system the warning will be shown here The water pump will automatically shut down if the water level gets too low The unit has two fuses for safety one for the fan motor and one for the water pump In the event the fan or water pump stops working the fuses should be checked to ensure they are intact In order to access the fuse box remove the contr...

Страница 9: ...rain trough To remove the two sides pads first pull them toward the middle of the unit until they pass the side retainer Then continue with the same procedure used to remove the center pad An inlet strainer is located on the bottom of the pump and should be inspected and cleaned periodically Cleaning the Cooling Pads Please make sure the electric power is turned off and cord disconnected from the ...

Страница 10: ...interlocks Before operating the unit read and observe all warning labels When troubleshooting make sure the unit is powered off and the power cord is disconnected from the power source Take extra precaution in damp areas to protect yourself from accidental electric shock Before turning the power on be sure that nothing is obstructing the fan blade Do not remove the control panel unless it is neces...

Страница 11: ... Gril 18 Valve 03 Louver 19 20 Inside Pipes 04 Blade 21 Water Level Sensor 05 Motor 22 Drain 06 Director 23 Electric Cord 07 Motor Seat 24 Water Inlet 08 12 Wheels 25 Cooling Pads 13 Control Box 26 Air Filter Mesh 14 Temperature Sensor 27 Water Block 15 Pump 28 Cooling Pads Brace 16 Buoy 29 Water Filter 30 Spray Pipe ...

Страница 12: ...ter Reservoir 37 gallons Width 56 in 142 cm Height 77 in 195 cm Depth 31 in 80 cm Unit Weight 249 lbs 113 kg Shipping Weight 282 lbs 128 kg Est Units 40 Container 23 C 200 Three Speeds Cooling Capacity 2 000 sq ft Maximum Air Delivery 7 500 CFM Fan Motor 1 3 HP 110 V 1 3 HP 220V Pump 0 3 HP 110V 0 3HP 220V Water Reservoir 15 gallons Width 32 in 82 cm Height 51 in 130 cm Depth 21 in 53 cm Unit Weig...

Страница 13: ...es sporting event sidelines for teams and aesthetically designed for use in outdoor patios and outdoor weddings there are myriad of uses for Cool A Zone such as but not limited to Industrial Warehousing Manufacturing Fabrication Shops Agricultural Military Sports Recreation Special Outdoor Events Restaurants Bars Automotive Aviation Home Patio Emergency Disaster Relief OSHA Compliance ...

Страница 14: ...14 www coolazone com CE Certificate ...

Страница 15: ...NATIONAL INC in USA Manufactured exclusively by Chief Executive Industries Corp in Taiwan Distributed exclusively by Cool A Zone Cool A Zone 9052 Long Point Road Houston TX 77055 info coolazone com coolazone com Toll Free 888 827 1675 Phone 713 968 9860 Fax 713 513 5279 ...

Страница 16: ..._ COMPANY __________________________________________ ADDRESS 1 __________________________________________ ADDRESS 2 __________________________________________ CITY _________________________ STATE _______ ZIP _____________ COUNTRY _________________________ WAYS TO REGISTER your product 1 Fill out the form online http www coolazone com product registration html 2 Fax this form to Cool A Zone at 713 ...

Страница 17: ...www coolazone com Cool A Zone info coolazone com 888 827 1675 9052 Long Point Houston TX 77055 ...

Отзывы: