background image

SETTING THE SENSOR 

 

Remember, your pool water level must be correct to 
continue: 

 

Step 6

:  Very slowly lower the sensor into the PVC sensor 

pipe until the water flow stops and the ON & 
SENSE lights flash every two seconds. 

Step 7

:  Once the water turns off, the SENSOR is now at 

the correct required position in the pipe.  Fasten 
the sensor lead to the pipe with a zip tie to 
prevent the sensor from moving up or down in 
the pipe. 

Step 8 

As an indicator for the position of the sensor in 
the pipe, mark the sensor lead with a 
pen/marker to indicate how far the sensor has 
been lowered into the pipe. 

 

Step 9

  If the pipe is in an area where debris can get into 

the pipe, it is recommended to put an end cap 
on the pipe but make sure it is not air tight. 

 

THE SENSOR IS NOW SET AT THE CORRECT LEVEL AND IS 
TO REMAIN AT THIS LEVEL TO ENSURE THAT THE YOUR 
POOL IS ALWAYS FILLED PROPERLY. 

 

IMPORTANT INSTALLATION STEPS: 
PLEASE FOLLOW STEPS 10 – 12 TO ADJUST THE WATER 
WITCH FROM TEST MODE TO OPERATING MODE.  

 

 

Содержание Water Witch

Страница 1: ...t Up Set Up Set Up Set Up Guide Guide Guide Guide utomated utomated utomated utomated p p p pool and ool and ool and ool and s s s spa water level pa water level pa water level pa water leveli i i ing...

Страница 2: ...ng of water witch Page 7 Setting the sensor Page 8 Operating Mode Dip Switch Settings Page 9 Internal Block Diagram Of control Back Page Contact Information Danger This unit is powered by a 240Volt AC...

Страница 3: ...ow that controls the flow of water Leveling Sensor Our patented leveling sensor designed to fit into 40mm and 50mm Class 9 pipe NOTE The sensor will not fit into 40mm Class 12 pipe When light is on st...

Страница 4: ...Diagram 3 Diagrams 3 4 5 and 6 Diagram 5 Diagram 6 Diagram 4 2...

Страница 5: ...sing the flow direction arrow indicated on the solenoid body Sensor Refer to the diagrams 5 6 on the opposite page for mounting of the sensor The suggested method of plumbing is two 40mm class 9PVC pi...

Страница 6: ...ct your distributor as 20 30 meter cables are available Custom made longer lengths can be manufactured Sensor Solenoid Connections TX GRD RX Sol1 Sol2 Cable Colour Code Reference Diagram7 Sensor Plug...

Страница 7: ...nd solenoid leads are normally 5 meters long with plugs attached for connections to the base of the control box as shown in Diagram 7 Water Witch 20 30 for the balance tank installs come with a 20 or...

Страница 8: ...or left solenoid right Step 3 Turn power and water supplies on The ON light will automatically come on and begin to flash Depending on what position the sensor is in will determine if the sense light...

Страница 9: ...ing up or down in the pipe Step 8 As an indicator for the position of the sensor in the pipe mark the sensor lead with a pen marker to indicate how far the sensor has been lowered into the pipe Step 9...

Страница 10: ...wer lead and switch on the power The Water Witch is now set to the correct water level and mode settings TABLE ONE Dip Switch Positions relevant to pool size 8 Mode Description Capacity In LTRS SWITCH...

Страница 11: ...Transformer Internal Of Control B Chip Dip switch Internal block Diagram Of Control Box Dip switch block Diagram 9...

Страница 12: ...ve any questions or you have come across a problem please call us on 1300 652 076 or 03 5023 3722 or you can refer to our web site for trouble shooting and technical help www cookeindustries com au Th...

Отзывы: