Layout and function
User manual
27
Electrical installed load ratings
The following table shows the electrical installed load ratings:
OGS
6.10
6.20
10.10
10.20
12.20
20.10
20.20
Table-top applian-
ces
Floor-standing
appliances
3N~ 400V 50/60Hz (3/N/PE)
Rated power consumption
[kW]
1,1 1,1 1,1 1,4 1,4 2,1 2,1
Rated current
[A]
2,5
2,5 2,5 3,2 3,2 4,7, 5,0
Fuse
[A]
16 16 16 16 16 16 16
recommended conductor
cross-section*
[mm
2
]
5G2.5 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5
3~ 230V 50/60Hz (3/PE)
Rated power consumption
[kW]
1,3 1,3 1,3 1,7 1,7 2,5 2,6
Rated current
[A]
4,5
4,5 4,5 5,8 5,8 8,7 9,0
Fuse
[A]
16 16 16 16 16 16 16
recommended conductor
cross-section*
[mm
2
]
5G2.5 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5 5G2.5
*recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.
Gas supply
The following table shows the values for the gas supply:
6.10
6.20
10.10
10.20
12.20
20.10
20.20
Table-top applian-
ces
Floor-standing
appliances
Fuels
Natural gas, liquid gas
Flue gas connection
Air conditioning system with safety shutdown
Appliance technical standards
The following table shows the technical standards for the appliance:
6.10
6.20
10.10
10.20
12.20
20.10
20.20
Table-top appliances
Floor-standing appliances
Degree
of
protection
IPX5
Approval mark*
Gastec QA, DIN GOST TÜV, SVGW, WRAS, UL, NSF, JIA, AGA
Noise emission
measured
[dBA]
<
70
*The appliance only displays those approval marks relevant to the country of use.