The lightning flash with an arrowhead symbol, within an equilateral 

triangle is intended to alert the user to the presence of uninsulated 
dangerous voltage within the product's enclosure that may be of 

sufficient magnitude to constitute a risk of electric shock to persons. 

 

 

The exclamation point within an equilateral triangle is intended to alert 

the user to the presence of important operating and maintenance 
(servicing) instructions in the literature accompanying the appliance. 

 

INFORMATION - 

This equipment has been tested and found to comply with 

limits for a Class A digital device, pursuant to part 15 of the FCC Rules & CE Rules. 
These limits are designed to provide reasonable protection against harmful 

interference when the equipment is operated in a commercial environment. 
This equipment generates, uses, and can radiate radio frequency energy and, if 

not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at 

his own expense. 

 

WARNING - 

Changes or modifications not expressly approved by the 

manufacturer could void the user’s authority to operate the equipment. 

 
CAUTION : 

To prevent electric shock and risk of fire hazards: 

 

Do NOT use power sources other than those specified. 

 

Do NOT expose this appliance to rain or moisture. 

 
 

This Installation should be made by a qualified service person and should confirm to all local codes. 

 

 
 

 

 

 
 

Содержание CC-5201

Страница 1: ...Manual CC 5201 1 Manual CC 5201 Date January 2011 Convision Systems GmbH...

Страница 2: ...de reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not install...

Страница 3: ...t for a long period a fire may be caused Do not install the camera on a surface that can not support it If the camera is installed on an inappropriate surface it may fall and cause injury Do not hold...

Страница 4: ...iew 9 Installation Procedure 10 Lens 10 Using an Auto Iris Lens 10 Using a C CS mount Lens 11 Connecting to a Monitor 12 Connecting to Power 13 Control via the RS 485 Interface 14 Camera Operation 14...

Страница 5: ...nded by manufacturer 6 Power source This product should be operated only from the type of power source indicated on the marking label Precautions Operating Before using make sure power supply and othe...

Страница 6: ...httime conditions to enhance the definition of the image Electronic IRIS The electronic Iris function enables continuous automatic control of the shutter between 1 60 1 50 1 120 000 sec Privacy Functi...

Страница 7: ...C Mount Adapter 4 Instruction Manual Overview Front View 1 Tripod Mounting Bracket Screw Hole Used to fix Tripod Mounting Bracket to the top of the camera 2 C Mount Lens Adapter Install this adapter t...

Страница 8: ...camera onto a bracket or tripod The screw sizes for this hole are as follows The Tripod Mounting Bracket can be unscrewed and installed on the top or bottom of the camera Make sure to use the Tripod M...

Страница 9: ...y or Night Mode by connecting an external signal to this port 8 MD Output Port Motion detection signal is output through this port 9 RS 485 Control Port The SETUP MENU can be controlled via this port...

Страница 10: ...lens surface clean as the picture quality suffers if there is dirt or fingerprints on the Lens Using an Auto Iris Lens 1 Strip 8mm of insulation from the end of the Auto Iris Lens cable 2 Strip 2mm of...

Страница 11: ...a simple modification is required When Using a CS Mount Lens Remove the protective cover from the front of this product and turn the CS Mount Lens clockwise to install it Focus the camera using the CS...

Страница 12: ...2 Turn the C Mount lens clockwise to install it 3 Focus the camera using the C Mount Lens and Back Focus controls 4 Set the lens selection switch located on the rear of the camera to either DC or VIDE...

Страница 13: ...ower as shown in the following figure For AC DC Power Check the standard power requirement before connecting to power Dual Power Type AC90 230V 50Hz 60Hz 4 5W AC 24V DC 12V AC 24V Class2 DC Power Type...

Страница 14: ...Rate Uart Mode Pet Pkt Initial Value 1 9600 8 NONE 1 ENABLE Note To control the camera use Pelco D protocol Go Preset 95 Enters into OSD menu or Set key function Camera Operation Menu Main Menu Expos...

Страница 15: ...t OFF or ON can be selected Shutter 1 60 NT FLC 1 250 500 1000 2000 4000 10000 can be selected When LENS is DC it is possible to select it Another becomes NOT USE It becomes 1 60 at NTSC It becomes 1...

Страница 16: ...AWC OFF to PUSH can be selected Another becomes NOT USE Return It returns to the Main Menu Day Night D N Mode AUTO DAY NIGHT EXT can be selected Filter DLY When it is AUTO 4 to 10 can be selected When...

Страница 17: ...N BLC automatically becomes effective on this screen Privacy Area 1 to 4 can be selected Mask OFF or ON can be selected Level When Mask is ON 0 to 15 can be selected It set the same value regardless o...

Страница 18: ...DOWN LEFT RIGHT Phase You can select a desired phase between 0 and 524 when the Sync menu is fixed to the AUTO mode Return It returns to the Main Menu o Title It moves by UP DOWN LEFT and RIGHT Chara...

Страница 19: ...9600 pbs Return It returns to the Main Menu Sync Two synchronisation modes are available INTERNAL and AUTO In AUTO mode it synchronises the video signal between cameras without a synchronous generato...

Страница 20: ...nitor If you have an intermediate device set the 75 Hi z properly and check the terminals Please check if an auto iris lens is being used and adjust the brightness level The camera surface is too hot...

Страница 21: ...ur 570 TV Lines B W Video out Level 1 0Vp p 75 Video 0 714Vp p Sync 0 286Vp p Burst Level 0 286 Vp p S N 50dB Min AGC Correct Off Sensitivity 0 08Lux Color 0 01Lux B W 0 001Lux Sens up F1 2 Sense Up M...