INSTALLING THE EXHAUST HOSE

Step 1:

Step 2:

Step 3:

Fit the exhaust hose to the hose

ends as shown in a clockwise direction.
Push the hose end onto the cooler, and
rotate so the slot locks onto the catch (Fig
5A).

Screw the round window adaptor

into position on the window attachment with
the screws (4) provided (Fig 5B).

Open the window and fit the

adjustable window attachment. Extend the
attachment as required and lock into place
with the screws (4) provided.  Ensure the
outlet is not obscured. The window
attachment can be installed horizontally or
vertically, to suit your window type.
Fit the hose end to the window attachment,
and lock into place as before (Fig 5B).

Note!

Note!

The minimum distance required

from the operating air conditioner to
any obstructing objects or walls is
50cm (Fig 6).

Keep the exhaust hose as short and
straight as possible and minimise
kinks.  This will maximise the cooling
performance.

Don

t use extension pieces for the

exhaust pipe as this will reduce the
cooling performance and possibly
result in damage to the air conditioner.

Hot air and possibly mist will be
emitted from the exhaust hose.

It is critical to the cooler

s

performance that the hot exhaust air is
completely removed from the space
being cooled.

5A

5B

50cm

6

4

CP12CS1 Portable Refrigerated Air Conditioner

The control panel is located behind the
remote control storage receptacle.
remove the remote control to access the
control panel.

To avoid damage to the control panel, do not operate with sharp objects.

NOTE!

7

8

CONTROL PANEL

DISPLAY PANEL

Press to turn the air

conditioner on and off

Press to cycle the fan

speed between high,

medium and low

Press to enter the

timer setting mode

and time

Press to cycle from

Cooling,Dehumidifying

and Fan modes.

Press + to increase,

- to decrease the

set temperature

In Timer mode, press

+ to increase, - to

decrease the timer

from 01-24 hours

In Cooling mode, press

at same time to toggle

between °C and °F

Power ON / OFF

button

Fan Speed

control button

Timer Set

button

Mode Select

button

Temperature / Timer

adjust buttons

Set

Temperature

Display

°C / °F

Indicator

Remote

Control

Receiver

Fan Speed

Indicator

Mode

Indicator

Warning

Light

Indicator

Timer Setting

Indicator

5

SEELEY INTERNATIONAL

OWNER’S MANUAL

Содержание CP12CS1

Страница 1: ...English CP12CS1 CP12CS1 OWNER S MANUAL Portable Refrigerated Air Conditioner...

Страница 2: ...f with household waste This product should be taken to your local recycling centre for safe treatment CONTENTS Introduction 1 Safety 2 Component location 3 Installing the exhaust hose 4 Control panel...

Страница 3: ...nditioning unit that supplies refrigerated air to a personal area within a room It is not intended to function as a house or room air conditioner Be sure the appliance has been securely and correctly...

Страница 4: ...re connecting the electrical power cord to a power outlet check that the air conditioner voltage is the same as your power supply refer to the rating label located on the side of the unit refer Fig 4...

Страница 5: ...l Remote Control Storage Air Filter Drain Air Intake Power Cord Exhaust Air Outlet Exhaust Hose Hose Ends x 2 Window Attachment 3 pieces Exhaust Fitting window end Rating Label COMPONENT LOCATION ON O...

Страница 6: ...ically to suit your window type Fit the hose end to the window attachment and lock into place as before Fig 5B Note Note The minimum distance required from the operating air conditioner to any obstruc...

Страница 7: ...er setting mode and time Press to cycle from Cooling Dehumidifying and Fan modes Press to increase to decrease the set temperature In Timer mode press to increase to decrease the timer from 01 24 hour...

Страница 8: ...ert new batteries Remove the batteries and replace with new ones If this does not solve the problem contact your nearest service centre for advice AAA making sure the and match the compartment marking...

Страница 9: ...ched on Step 2 Step Step 4 Cooling mode Dehumidifying mode Fan mode Step 5 Lift up the air outlet vent ready for use 3 Press the ON OFF button on the remote control or ON OFF button on the control pan...

Страница 10: ...ng Press the or buttons to increase or decrease the time in 1 hour increments from 1 24 hrs After 5 seconds the display will stop flashing and the TIMER symbol will be lit on the display panel Fig 8 W...

Страница 11: ...e body clean Never use aggressive chemicals spirits detergents chemically treated cloths or other cleansing solutions These substances could possibly damage the cabinet Use a vacuum cleaner or tap the...

Страница 12: ...s cool as it once was Are the filters dusty or dirty restricting the airflow Is the air inlet or outlet blocked Is the room temperature below the set temperature The air conditioner is too noisy Is th...

Страница 13: ...RAM SEELEY INTERNATIONAL CONVAIR PORTABLE AIR CONDITIONER Model s Function Cooling Capacity Watts Air Flow Volume m hr 3 Power Supply Rated Input Power Watts Fuse Type Refrigerant Type Charge kg Water...

Страница 14: ...e with the instructions in the Owner s Manual The addition of any third party device or the removal or the alteration of any of our components will void this warranty In addition the warranty granted...

Страница 15: ...Our liability under this warranty is limited to the extent permitted by law That is to the extent that it is fair and reasonable if the Goods are not of a kind ordinarily acquired for personal domesti...

Страница 16: ...0 526 410 seeleyinternational com It is the policy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult wit...

Отзывы: