background image

If there are two of the same air
conditioners installed, they cannot be
controlled separately. When you operate
either remote, it will turn on both air
conditioners if they are both within signal
range (6 metres).

Don’t let the remote control drop onto
hard surfaces or be subjected to sudden
shocks in any way. The warranty does not
cover misuse or accidental damage.

Don’t place the remote control in direct
sunlight, or near extremes of temperature.
This will affect the control’s temperature
reading.

Don’t allow the remote control to get wet.

Don’t place near strong electromagnetic
waves.

Don’t mix old and new batteries!
If the remote control will not be used for a
long time, remove the batteries to avoid
corrosion.

Care of your remote control

Preparation before operation

During Operation

Remove the battery cover and insert new
batteries

.

Remove the batteries and replace with new
ones.  If this does not solve the problem
contact your nearest service centre for
advice.

(AAA), making sure the + and - are

matching the compartment markings (Fig 9)

If the remote control will not operate the air
conditioner, the batteries may need to be
replaced.

The air conditioner must be plugged in

and switched on for the remote control to
operate the air conditioner. To use, point at
the signal receiving window on the front
panel and press the remote button. The air
conditioner will “beep” when a signal has
been received. If there is no beep, press the
remote button again, ensuring it is within
range (6 metres) of the air conditioner.

Note!

!

NOTE:

WASTE BATTERIES SHOULD

BE DISPOSED OF CORRECTLY

REMOTE CONTROL

8

Signal
transmission point

Temperature
adjust buttons

Sleep mode button

Swing button

Fan speed
adjust button

Mode buttons
(Cool-Dehumidify-Fan)

Timer on / adjust
button

Power ON / OFF
button

Battery
compartment

Battery cover

9

CP10-12CW1 Portable Refrigerated Air Conditioner

6

®

Note!

Important!

Step 6:

In Cooling mode, the fan will continue

to run even when the compressor has
cycled off.

The air conditioner is fitted with 2

sets of air direction vanes.

Horizontal vanes will cycle left to right

automatically by pressing the SWING button
on the remote control or control panel (Fig
7, 10).

Vertical vanes - carefully move the vanes

to the desired position by hand (Fig 11).

During cooling mode, water will

collect in the air conditioner’s tank. This
water is recirculated and some will be
exhausted out with the hot air, but will slowly
fill up the tank. This occurs more quickly in
humid conditions.  If the tank should fill, the
‘water full’ indicator will be lit on the control
display, the unit will ‘beep’ and then shut
down. The cooler cannot be restarted until
the water tank is drained.  Refer to the
Maintenance section for draining the tank
should this occur.

!

!

Starting the air conditioner

Step 1:

Ensure the cooler is plugged in

and switched on.

!

!

!

Step 2:

Step 3:

Cooling mode

Dehumidifying mode

Fan mode

Step 4:

!

Step 5:

Press the ON/OFF button

on the remote control or ON/OFF

button on the control panel to start the air
conditioner.

Press the MODE button

on

the control panel or remote control to
select the desired operating mode (Fig.7
&10):

- refrigerated

cooling

- for extracting

moisture from the air

- Fan only operation (no

cooling)

Press

/ - on the control panel

or

/

on the remote control to select

the desired operating ‘set’ temperature.

In Cooling mode, cooling will occur if the
set temperature is less than the room
temperature.

Do not set the cooling temperature

too low. This will consume more power.
24°C is the recommended set
temperature, with high fan speed.

Changing the set temperature will

have no effect in DEHUMIDIFYING or
FAN modes.

Press the FAN SPEED button

on the control panel or remote control

to adjust the fan speed. Each press will
cycle the fan speed between low and
high.

+

p q

The set temperature range is 16°C-31°C

Tip

Note!

OPERATION

Step.2

Step.8

Step.3

Step.5

Step.4

Step.7

Step.6

10

11

SEELEY INTERNATIONAL

OWNER’S MANUAL

7

Содержание CP10CW1

Страница 1: ...English CP10 12CW1 CP10CW1 CP12CW1 OWNER S MANUAL Portable Refrigerated Air Conditioner...

Страница 2: ...Waste electrical products must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment CONTENTS Introduction 1 Safety 2 Component locati...

Страница 3: ...Convair cooler is a portable air conditioning unit that supplies refrigerated air to a personal area within a room It is not intended to function as a house or room air conditioner Be sure the applia...

Страница 4: ...e connecting the electrical power cord to a power outlet check that the air conditioner voltage is the same as your power supply refer to the rating label located on the back of the unit refer Fig 4 E...

Страница 5: ...r Display Panel Control Panel Air Filter Air Filter Drain Air Intake Power Cord Exhaust Air Outlet Exhaust Hose Window Attachment Exhaust Fitting window end Screws 6 Rating Label Cord Storage Hooks CO...

Страница 6: ...achment can be installed horizontally or vertically depending on the window type Note Note The minimum distance required from the operating air conditioner to any obstructing objects or walls is 50cm...

Страница 7: ...me Press to turn the air conditioner on and off Press to increase to decrease the set temperature Press to cycle the fan speed between low and high Power ON OFF button Timer Set button Mode Select but...

Страница 8: ...batteries Remove the batteries and replace with new ones If this does not solve the problem contact your nearest service centre for advice AAA making sure the and are matching the compartment marking...

Страница 9: ...ler is plugged in and switched on Step 2 Step 3 Cooling mode Dehumidifying mode Fan mode Step 4 Step 5 Press the ON OFF button on the remote control or ON OFF button on the control panel to start the...

Страница 10: ...e cooler must be plugged in and ready to operate With the air conditioner ON press the TIMER button on the remote control or control panel The control panel display will flash and show the time settin...

Страница 11: ...ever use aggressive chemicals spirits detergents chemically treated cloths or other cleansing solutions These substances could possibly damage the cabinet Use a vacuum cleaner or tap the filter lightl...

Страница 12: ...cool as it once was Are the filters dusty or dirty restricting the airflow Is the air inlet or outlet blocked Is the room temperature below the set temperature The air conditioner is too noisy Is the...

Страница 13: ...on Cooling Capacity Watts Air Flow Volume m hr 3 Power Supply Rated Input Power Watts Fuse Type Refrigerant Type Charge kg Water Ingress Protection Rating Weight kg Dimensions mm width depth height CP...