Never try to dismantle the air conditioner yourself.
Problem
Check
The air conditioner does not
run.
Is the air conditioner plugged in?
Is there a power failure?
Is the "WATER FULL" error code flashing?
Drain the tank as shown (Fig 12).
The air conditioner has little
effect (firstly ensure that the
room being cooled is not too
large for the stated capacity
of the air conditioner).
Is there direct sunshine? Remember to close
curtains or blinds.
Are windows or doors open?
More people in the room will generate more
heat.
Is there something in the room producing
excessive heat?
Is the exhaust fitted correctly or obstructed?
All exhaust air needs to be completely
removed from the room.
The air conditioner is not as
cool as it once was.
Are the filters dusty or dirty, restricting the
airflow?
Is the air inlet or outlet blocked?
Is the room temperature below the set
temperature?
The air conditioner is too
noisy.
Is the air conditioner positioned unevenly, so
as to create vibration?
Is the floor beneath the air conditioner
uneven?
It is possible that the overheat protection for
the compressor is on. Wait for it to reset.
Note: when changing between different modes
(cooling to fan or dehumidifying mode etc) the
compressor will turn off. A 3 minute delay will
occur before the compressor will turn on again.
The compressor will not run.
In case of problems that cannot be fixed by using the above guide, or if service
on your air conditioner is required, please contact your dealer or designated
service agent.
TROUBLESHOOTING
Is the room temperature below the set
temperature?
CP10-12CW1 Portable Refrigerated Air Conditioner
10
SPECIFICATIONS
†
Based on manufacturer's test results using the Air Enthalpy method
As a policy of continual product improvement, this manual, its contents and specifications are subject to change without notice.
WIRING DIAGRAM
SEELEY INTERNATIONAL
PORTABLE AIR CONDITIONER
330 / 370 / 830
330 / 370 / 830
Model(s)
Function
Cooling Capacity (Watts)
†
Air Flow Volume (m / hr)
3
Power Supply
Rated Input Power (Watts)
Fuse Type
Refrigerant Type / Charge (kg)
Water Ingress Protection Rating
Weight (kg)
Dimensions (mm)
(width / depth / height)
CP10CW1
CP12CW1
Personal Cooling
Personal Cooling
2900 (10,000 Btu/hr)
3500 (12,000 Btu/hr)
350
380
220-240V ~ 50Hz
220-240V ~ 50Hz
1110
1340
3.15A / 250V
3.15A / 250V
R410A / 0.47
R410A / 0.52
3.2
3.2
0.8
0.8
IP20
IP20
High Side Pressure - Maximum (MPa)
Low Side Pressure - Maximum (MPa)
26
26