background image

GB

51

Lighting Instructions

Feeding Wood:

Split logs

Length: 25-50 cm
Diameter: 6-9 cm
Normal weight: 2.5 kg/hour
Max amount: 3.5 kg/hour
(max 3
pieces per load. Max 3 kg per insertion).

Following loads

First and second load

adding wood

The first load of logs after lighting should not be put on until the start-up 
fire has turned to embers and no yellow flames are visible. At the first and 
second loads of wood after lighting, it is recommended to use 3 pieces 
of wood to build up a proper glowing bed of embers and get the stove to 
operating temperature. When a proper glowing bed of embers is achieved, 
you can continue to add 2 pieces of wood at a time.  
1.  Open the door.
2.  Insert one piece of wood diagonally on the bottom and place the 

remaining logs on top.

3.  The damper must be completely open until the logs turn black and catch 

fire. This can take about 3- 5 min. The damper can then be closed. The 
conditions for controlling combustion vary depending on the firebox 
temperature, the moisture content of the wood and the draft in the 
chimney.

4.  A nominal output of 8 kW is obtained when the combustion air damper 

is at 2 dots. 2 logs with a combined weight of 2 kg can be added at the 
same time every 50 minutes.

5.  The lowest output is obtained when the combustion air damper is at 1 

dot and 2 logs are lit. In this operating position, it is important that the 
combustion air damper is fully open for the first 3-5 minutes so that 
the wood has time to burn properly before the supply of combustion 
air is reduced. A condition for regulating the output is a thick bed of 
embers and high temperature in the firebox. When the fire has died 
down to embers, and no yellow flames are visible, more wood should be 
added.

Содержание C i50

Страница 1: ...Ci50 Ci51 www contura eu Operation instructions...

Страница 2: ...e the window open for a few minutes until the fire has caught properly 1 Open the damper completely to max 2 The start up fire must consist of approx 11 pieces of kindling of varying dimensions with a...

Страница 3: ...op 3 The damper must be completely open until the logs turn black and catch fire This can take about 3 5 min The damper can then be closed The conditions for controlling combustion vary depending on t...

Страница 4: ...insulating properties It contains a certain amount of water that evaporates during the first lighting Whilst this happens combustion may seem to be slow and soot may build up on the insulation panels...

Страница 5: ...ustion is also poor layers of soot and tar build up in the chimney and could at worst lead to a chimney fire In addition it causes the glass of the insert to soot and may cause discomfort to those liv...

Страница 6: ...traight up The ash must be stored in a fireproof container with a lid for at least one week before being disposed of The grate and other cast iron components can be cleaned using a wirebrush It is imp...

Страница 7: ...installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of an alarm must not be considered a substitute for either installi...

Страница 8: ...modate the weight of the stove and its chimney if the chimney is not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non comb...

Страница 9: ...ns given under Warning Note above Air Controls Manually operated air control can be managed by adjusting the air control valve to increase decrease the air flow to the stove Use of fireguard When usin...

Страница 10: ...himney fires should not occur However if a chimney fire does occur turn off the stove immediately and isolate the mains electricity supply if applicable and tightly close the doors of the stove This s...

Страница 11: ...going Check that the combustion air damper is open fully Check that the ash box is not overfilled An overfilled ash box will block parts of the fireplace s air supply After sweeping the smoke outlet o...

Страница 12: ...to property and personal injury The ash pan must be emptied when it is full If this is not done the air supply can become blocked resulting in poor function In serious cases ash can find its way out t...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...E AB Box 134 285 23 Markaryd Sweden www contura eu Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition...

Отзывы: