GB
71
INSTALLATION DISTANCES
C26K Low
Installation distances
4
42
E 150
A 1116
B 1033
F 410
C 188
D 85
Utv Ø150
502
462
1312
582
23
00
G 90
Combustible roof
Combustion air hose
(accessory)
*To prevent discolouration of painted fire walls, we recommend the same side distance as to combustible walls.
A = height from floor to chimney connection upwards
B = height from floor to c/c chimney connection rear
C = distance from back to c/c chimney connection upwards
D = distance from back to chimney connection rear
E = distance from back to hole in guide plate
F = height from floor to air inlet connector (410 mm)
G = distance to hole in guide plate
28
8
100
600
890
500
400
300
200
3
00
4
00
5
00
200
Combustible wall
Permitted area for
combustible material
435
120
89
0
810
Combustible wall
23
8
50
300*
590
Fire-retardant wall of
brick or concrete
3
65
50
795
74
0
Fire-retardant wall of
brick or concrete
Place the stove on the
hearth plate and check
that the installation
distances are not less
than those that are given
in the figures below. The
minimum distance in
front of the stove opening
to combustible parts of
the building or interior
decoration must be at least
1 m.
When top connecting
a steel flue, please
refer to the particular
manufacturer's installation
instructions. Observe
the safety distance to
combustible material that
the steel flue requires.