Remote-i Net
3. The Guardus starts emitting a series of “bips” without the COMMUNICATION LED lighting
up. What has happened?
This is not a
Remote-i Net
but a
Guardus
signal. What it is trying to tell you is that the position in
which the
Guardus
was placed on the
Remote-i Net
metal receptacle caused a faulty contact. This
situation is temporary and soon after the end of the 9 “bips” sequence the
Remote-i Net
will try
again to connect with the
Guardus
. Just wait as everything will return to normal after a few
seconds.
4. The Guardus was placed on the Remote-i Net metal receptacle but the COMMUNICATION
LED began to flash orange and nothing happened. What is the Remote-i Net trying to signal
with this?
The
Remote-i Net
, upon detecting that a
Guardus G
or
Guardus T
was placed on the metal
receptacle, tries to read some internal information which gives the remote computer address which
should receive the data download. If these data are not recorded on the
Guardus
, the
Remote-i Net
will try to find out whether they are programmed inside itself.
If the
Remote-i Net
still does not find sufficient information to attempt communication with the
remote computer, the COMMUNICATION LED will signal this by flashing orange immediately
after contact with
Guardus
. This signaling will remain while the
Guardus
is in contact with the
metal receptacle.
What should be done:
a. obtain the IP address and the number of the remote computer port which was programmed
to receive the
Guardus
downloads of your company. If you do not know how to obtain this
information, establish contact with the person responsible for your local network and give
the name of the remote computer you wish to use;
b. use this information (IP address and port number) to program the
Remote-i Net
as
described in the item “CommCenter addressing" on page 10, or
c. reprogram the
Guardus
so that it can start storing the IP address and the port number
To program
Guardus G
/
Guardus T
, use the application corresponding to each device. The
Guardus G, for example, is reprogrammed through PROGuard.
Contronics