Contronics Remote-i Net Скачать руководство пользователя страница 17

Remote-i Net

3. The Guardus starts emitting a series of “bips” without the COMMUNICATION LED lighting

up. What has happened?

This is not a 

Remote-i Net

 but a 

Guardus

 signal. What it is trying to tell you is that the position in

which the 

Guardus

 was placed on the 

Remote-i Net

 metal receptacle caused a faulty contact. This

situation is temporary and soon after the end of the 9 “bips” sequence the 

Remote-i Net

 will try

again to connect with the 

Guardus

. Just wait as everything will return to normal after a few

seconds.

4. The Guardus was placed on the Remote-i Net metal receptacle but the COMMUNICATION

LED began to flash orange and nothing happened. What is the Remote-i Net trying to signal
with this?

The 

Remote-i Net

, upon detecting that a 

Guardus G

 or 

Guardus T 

 was placed on the metal

receptacle, tries to read some internal information which gives the remote computer address which
should receive the data download. If these data are not recorded on the 

Guardus

, the 

Remote-i Net

will try to find out whether they are programmed inside itself.

If the 

Remote-i Net

 still does not find sufficient information to attempt communication with the

remote computer, the COMMUNICATION LED will signal this by flashing orange immediately
after contact with 

Guardus

. This signaling will remain while the 

Guardus

 is in contact with the

metal receptacle.

What should be done:

a. obtain the IP address and the number of the remote computer port which was programmed

to receive the 

Guardus

 downloads of your company. If you do not know how to obtain this

information, establish contact with the person responsible for your local network and give
the name of the remote computer you wish to use;

b. use this information (IP address and port number) to program the 

Remote-i Net

 as

described in the item “CommCenter addressing" on page 10, or

c. reprogram the 

Guardus

 so that it can start storing the IP address and the port number 

To program 

Guardus G

 / 

Guardus T

, use the application corresponding to each device.  The

Guardus G, for example, is reprogrammed through PROGuard.  

Contronics

13

Содержание Remote-i Net

Страница 1: ...Operation Manual Remote i Net...

Страница 2: ......

Страница 3: ...CP server on the local network 5 Reconfiguring the Remote i Net for use without a DHCP server 6 Remote i Net Configuration Program 6 List of Remote i Net devices found 8 Identification of the selected...

Страница 4: ......

Страница 5: ...external modem and a telephone line dial up in order to connect directly with the remote computer Remote i Modem Evolution of the Serial model bringing a built in modem The connection is carried out i...

Страница 6: ...installed fulfills the requirements necessary for physical connection y electrical AC socket supplying 110 or 220V y local network access point The power source provided with the Remote i Net leaves...

Страница 7: ...e download process y LINE which shows the exchange of information between the Guardus and the remote computer y POWER which indicates that the equipment is switched on During operation there may be a...

Страница 8: ...ed during the entire download process and the user shouldn t remove the Guardus from the metal receptacle as this will interrupt the operation 5 when the remote computer is connected to the Remote i N...

Страница 9: ...tes and disciplines the distribution of addresses when the quantity of machines connected to the same local network is very high more than 10 machines Often for small installations a DHCP server is no...

Страница 10: ...work router Having obtained this information use a RiNetConfig program to reconfigure your Remote i Net It is available on the same menu as the PROGuard program Remote i Net Configuration Program The...

Страница 11: ...to scan the local network in search of Remote i Net devices If a device of this type is found it will appear on the list as shown in the figure below If more that one Remote i Net is connected at the...

Страница 12: ...will be shown grouped according to type of information One of these groups is the unique identification of each device which is shown on the upper right part of the main screen Local addressing of the...

Страница 13: ...ds IP address Network mask and Standard router Example of the local fixed addressing the numbers may vary Contronics 9 Important Note If the local network where the Remote i Net will be installed does...

Страница 14: ...tion with the CommCenter an option would be to use a program address in the memory of the Remote i Net itself The Remote i Net leaves the factory without any CommCenter address programmed as shown in...

Страница 15: ...rmation shown or edited on the main screen of the Remote i Net configuration program remains stored only inside each specific device No information is recorded on the computer which is being used for...

Страница 16: ...light up call Technical Assistance see contact information on page 19 and report the problem 2 The Remote i Net came on but the 3 LEDs remained lit after the initial 3 seconds What should be done This...

Страница 17: ...ta are not recorded on the Guardus the Remote i Net will try to find out whether they are programmed inside itself If the Remote i Net still does not find sufficient information to attempt communicati...

Страница 18: ...ource of the problem can be verified 6 The COMMUNICATION LED is red without flashing Is it OK to remove the Guardus from the Remote i Net metal receptacle No While the COMMUNICATION LED is lit in red...

Страница 19: ...a Open the program RiNet_Config and click on Update b Deselect the option Use DHCP server if it is selected c In Devices click on a Remote i and fill in the fields IP Address Network mask and Standar...

Страница 20: ...work will be affected 14 So that means that I can have 50 clients spread around the country sending wand data to my company without any of these clients needing to configure the router or firewall Exa...

Страница 21: ...y request that it be used moderately since there are thousands of Remote i Nets spread worldwide which also use this address for tests 18 Is there an easy way to find out the internet address of my co...

Страница 22: ...sions H x W x L 30 mm x 68 mm x 105 mm Weight 315 g Operation temperature 5 70 celsius Humidity tolerance up to 95 without condensation Power supply external source of 9 V 500 mA Communication Etherne...

Страница 23: ...ether the CommCenter program is active y whether the Remote i Net local network and the remote computer local network are interconnected y whether the situation observed is listed in the section Frequ...

Отзывы: