background image

Appendix D: FCC Statement

XW-112™ Wi-Fi Water Detector Users Manual

Appendix D: FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1.

This device may not cause harmful interference.

2.

This device must accept any interference received, including interference that may cause 
undesired operation.

Warning

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can radiate 
radio frequency energy and, if not in-stalled and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures: 

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into a relay on a circuit different from where the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Notice

Changes or modification not expressly approved by the party responsible for compliance could void the 
user’s authority to operate the equipment.

RF Exposure Information

This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled 
environment. The antennas used with this transmitter must be installed to provide a separation distance 
of at least 20cm from all persons and must not be located or operating in conjunction with any other 
antenna or transmitter.

Canadian License-Exempt Radio Apparatus (RSS-GEN)

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the 
following two conditions: (1) this device may not cause interference, and (2) this device must accept any 
interference, including interference that may cause undesired operation of the device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts 
de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire 
de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le 
brouillage est susceptible d'en compromettre le fonctionnement.

Page 32

Xytronix Research & Design, Inc.

Содержание XW-112

Страница 1: ......

Страница 2: ...XW 112 Wi Fi Water Detector Users Manual XW 112 User Manual Revisions Revision Description 1 0 Initial release Page 2 Xytronix Research Design Inc...

Страница 3: ...on anytime to active the access point mode Then with a PC or smart phone connect to and access the XW 112 s internal web server The XW 112 will always be accessible this way regardless of the mode to...

Страница 4: ...5 sensor can detect the presence of water and provides a relay output for control of an external device The sensor has two exposed stainless steel electrodes which detect the presence of water Althoug...

Страница 5: ...r motors or AC wiring The GRI 2605 has an internal relay Its contacts green white wires are closed when the sensor is dry When the sensor is dry the digital input will be On When water is detected the...

Страница 6: ...he circuit requires power from a 5 volt DC wall transformer and will not operate from batteries alone Installing batteries however allows the XW 112 to sent a power fail email notification if the AC p...

Страница 7: ...eb browser http 192 168 1 2 setup html After the page is requested a password prompt will appear Enter the username and password The username is admin and the password is webrelay password is case sen...

Страница 8: ...as assigned To begin press the WPS button on your wireless router or access point You will generally have about two minutes to connect wireless devices to the network with WPS Now remove the cover of...

Страница 9: ...your network administrator Press the Submit button at the bottom of the page The XW 112 s internal web server is always enabled and accessible Navigate to the Water Sensor tab On the Email Alerts set...

Страница 10: ...cessed any time Note that if you are accessing the unit as an access point the above IP address will work even if you have previously changed the IP address or port in the setup pages If you are acces...

Страница 11: ...o load on the battery The calculations are made for alkaline AA batteries with a usable capacity of 2000mAH When using other types of batteries or in cold conditions the displayed estimate may be in e...

Страница 12: ...to make a fresh scan of available networks Note The Refresh button is inactive if the XW 112 itself is an access point Security Type of authentication used by the access point for connections Securit...

Страница 13: ...not always be the same so client devices may not be able to find the server For this reason servers usually use an IP address that is fixed and does not change The XW 112 is a server and manual IP ad...

Страница 14: ...the IP address is specified enter it in this format aaa bbb ccc ddd For numbers that are less than 100 preceding zeros should not be included for example enter 80 rather than 080 This field can be up...

Страница 15: ...the end of this section for more information Certificate Request Port The certificate server is a server that has been configured to deliver the Client Certificate Key and CA when requested by the XW...

Страница 16: ...erver rather than the web server initiating communications to the XW 112 This has two main benefits First the web server does not need to know the IP address of XW 112 This means that XW 112 can get i...

Страница 17: ...email server typically over the internet STATUS NOTIFICATION Email on Low Battery When the estimated battery life reaches 15 an email alert is sent To conserve already meager energy resources only one...

Страница 18: ...is sent to these addresses Test Email Pressing this button will submit any changes to the email settings and trigger an alert email to be sent to the configured email addresses The result of the test...

Страница 19: ...lid and has a proper DNS record for the SMTP Server host provided Error establishing connection Error configuring security on SSL socket or error creating socket Error with SSL handshake Could not suc...

Страница 20: ...t entered identically in both fields the password will not be changed CONTROL PAGE Enable Control Password The Control Page is normally viewed without entering a password For security purposes a passw...

Страница 21: ...se email messages to be sent Off No email messages will be sent due to a water alarm On Email notifications will be sent when the water alarm changes from dry to wet or wet to dry Up to three email ad...

Страница 22: ...pulsed when the sensor becomes wet Send pulse command when sensor changes The remote relay is pulsed when the sensor changes state Send toggle command when dry The remote relay changes state when the...

Страница 23: ...to control on the device Note To control WebRelay s relay enter in the number 0 Remote Services The XW 112 can be configured to send messages to other ControlByWeb products or servers that are located...

Страница 24: ...ing the default IP address the user would enter http 192 168 1 2 If the IP address is changed from the default the user must use the new IP address Note that if any port is used other than the default...

Страница 25: ...0x57 0x65 0x62 5 1 Initial Contact The initial contact request is sent to discover ControlByWeb devices on the network It is recommended to send this message multiple times in environments where many...

Страница 26: ...es ASCII String no null terminator xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx IP Address 4 bytes Network endianness 0xc0 0xa8 0x01 0x02 192 168 1 2 Subnet 4 bytes Network endianness 0xff 0xff 0xff 0x00 255 255...

Страница 27: ...sage ID 1 byte Setup successful response 0x04 MAC Address 6 bytes Binary version 0x00 0x0c 0xc8 0x00 0x00 0x00 Error Response Header 12 bytes ASCII String ControlByWeb Message ID 1 byte Command not re...

Страница 28: ...tected Setup Connectivity Always connected Remote Server ControlByWeb s X 600 or cloud based server Remote Relays Control relays on other ControlByWeb products Polling state xml only when web server i...

Страница 29: ...s Switch Status Alerts Dry to wet or wet to dry transitions power fail Environmental Location Indoor use or NEMA 4 protected location Using Alkaline Batteries 18 C to 55 C 0 F to 130 F Operating Tempe...

Страница 30: ...r scanning for any purpose other than the personal use by the purchaser of this product Xytronix Research Design Inc assumes no responsibility for any errors that may appear in this document Whereas r...

Страница 31: ...e purchaser as long as the product is shipped within the continental United States If the product is shipped outside of the continental United States or the product was shipped more than one year earl...

Страница 32: ...ment and receiver Connect the equipment into a relay on a circuit different from where the receiver is connected Consult the dealer or an experienced radio TV technician for help Notice Changes or mod...

Страница 33: ...XW 112 Wi Fi Water Detector Users Manual Appendix E Mechanical Dimensions Appendix E Mechanical Dimensions Xytronix Research Design Inc Page 33...

Отзывы: