Package contents

•  C4-Z2C ZigBee Contact Sensor
•  Four wall mounting screws
•  Four plastic dry wall anchors
•  AA batteries (2)

Requirements

•  Composer Pro 2.10.0 or higher

Features

The ZigBee Contact Sensor (Z2C) is a single device that 

combines the features of:

•  Remote contact sensors (up to four)
•  Remote thermistors (one)
•  Internal contact (internal magnetic reed switch)
•  Internal thermistor and humidistat

Any of these inputs can be used to trigger and control automated 

events—such as sending an e-mail or turning on a cabinet light 

when its door is opened—throughout the Control4 system.

You can position this wireless device anywhere you need contact 

connections or climate reporting. 

As a contact sensor

The device contains five contacts: one internal contact and 

connections for four wired contacts. 

The internal contact is a magnetic reed switch. To use this internal 

contact, the Z2C should be mounted so that the indention (along 

the same edge as the identify button) comes in close proximity 

to a mounted magnet (not included) in a fully closed state (door 

is closed). When the door opens, the magnetic connection is lost, 

and that state change is pushed to the system.

Wiring guide:

Contact 1  ->  Pin C1 

Contact 2  ->  Pin C2 

Contact 3  ->  Pin C3 

Contact 4  ->  Pin C4 

(All can use either of the Cm pins as Common)

As a thermistor and humidistat

The device contains an integrated thermistor and humidistat, 

as well as a connection for an external thermistor, allowing it to 

be used almost anywhere to report environmental conditions 

or to inform the climate control system. The thermistor 

senses temperatures from 32°F to 104°F (0°C to 40°C), and 

the humidistat senses humidity from 5% to 90%. The device 

checks the temperature and humidity every five minutes. If the 

temperature has changed more than 0.9°F (0.5°C), the device 

reports the new temperature and humidity values.

Notes: 

•  A value of -40° in the 

Remote Temperature

 field 

could indicate either a negative temperature or that 

no remote thermistor is connected.

•  The integrated humidistat will return a zero value 

after the device is rebooted until the actual humidity 

value can be reported.

•  See “Sample wiring configurations” below for an 

example of an external thermistor connection.

•  To display the temperature and/or humidity in 

Navigator, add the “Temperature Display Driver 

(OS 2.10+)” to the project and connect the driver’s 

temperature driver to the Z2C.

•  Given the variations in temperature and humidity 

measurements and environments, it may be 

necessary to independently test and verify the  

local and remote temperature and humidity. The 

properties 

Local Temperature Offset

Remote 

Temperature Offset

, and 

Local Humidity Offset

 can 

be used for this purpose.

Important safety instructions

Caution! 

You should install this device in accordance 

with all national and local electrical codes.

Caution! 

Improper use or installation of this device can 

result in loss of and damage to property.

Important: 

This product is not intended for direct 

connections to AC mains (120V/220V). Refer to the 

specifications.

Important: 

You must operate this device in accordance 

with the instructions and specifications in this 

installation guide.

 Important: 

Using this product in any manner other than 

outlined in this document voids your warranty. Also, 

Control4 is 

not

 responsible or otherwise liable in any 

way for any damage resulting from the misuse of this 

product. See 

ctrl4.co/warranty 

for details.

ZigBee Contact Sensor

Installation Guide

Содержание C4-Z2IO

Страница 1: ...or IR cables can be spliced together in parallel not in series to increase the number of controlled devices Be aware that these connected emitters cannot be controlled independently but will all fire...

Страница 2: ...e acts as a ZigBee mesh extender and router It is designed to extend the ZigBee network into distant or hard to reach areas The Z2IO provides support for up to 32 nodes in its ZigBee routing table Thi...

Страница 3: ...e with any water based residential paints Do not clog the cover assembly vent holes with paint Accessories External thermistor ZCA EXT10A AC DOTS1 W AC PMT51 W Installing 1 Place the device in a locat...

Страница 4: ...f the cover until it snaps and locks into place with the tray 12 For ZigBee to IR connect any IR emitters to the two IR ports then affix the emitter head to the IR window on the device to control such...

Страница 5: ...Sets which scale is used to calculate the temperature used in the Local and Remote Temperature properties described below and affects only the Properties tab s settings Options include Fahrenheit and...

Страница 6: ...e action buttons will trigger the corresponding relay to open Troubleshooting If the device is not working Reboot the device by disconnecting power then re connecting power Check for proper wiring See...

Страница 7: ...he humidistat senses humidity from 5 to 90 The device checks the temperature and humidity every five minutes If the temperature has changed more than 0 9 F 0 5 C the device reports the new temperature...

Страница 8: ...vice in a location which ensures the following Easy access to any externally connected wires ZigBee mesh networking efficiency Note Make sure the device has good ZigBee wireless reception by 1 ensurin...

Страница 9: ...Design view then connect the generic driver to the appropriate connection on the C4 Z2C device in Connections view 4 For programming use these events Missed Checkin Triggers when the device misses a c...

Страница 10: ...checked in with the controller Missed Checkin Limit Sets the number of times the checkin is missed before triggering the Missed Checkin programming event Actions tab Buttons located on the Actions tab...

Страница 11: ...latory Safety information To review Regulatory information for your particular Control4 products see the information located on the Control4 website at ctrl4 co reg Patent information Applicable paten...

Страница 12: ...e on a device that can view PDFs DATA SHEET ctrl4 co z2io ds MOST RECENT VERSION ctrl4 co z2io ig Regulatory Safety information To review Regulatory information for your particular Control4 products s...

Страница 13: ...ventilation Installer conform ment aux instructions du fabricant 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce he...

Страница 14: ...ord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Confiez tou...

Страница 15: ...cal equipment such as tape recorders TV sets radios computers and microwave ovens if placed in close proximity 19 Ce produit peut interf rer avec des appareils lectriques tels que les magn tophones t...

Страница 16: ...equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Pa...

Страница 17: ...fication number signifies that FCC and Industry Canada technical specifications were met FCC ID R33C4Z2IO IC 7848A C4Z2C This equipment must be installed by qualified professionals or contractors in a...

Страница 18: ...Les utilisateurs finaux doivent suivre les instructions de fonctionnement sp cifiques pour satisfaire la conformit aux expositions RF L quipement ne doit tre utilis ou install des endroits o il est n...

Страница 19: ...e Council Directive s is declared EMC 2014 30 EU Electromagnetic Compatibility EMC Directive Emissions EN 55032 2012 Immunity EN 55024 2010 A1 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 Safety 2006 95 E...

Страница 20: ...Conseil s est d clar e EMC 2014 30 compatibilit lectromagn tique CEM UE missions EN 55032 2012 immunit EN 55024 2010 A1 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 S curit 2006 95 CE Directive Basse Tens...

Страница 21: ...st EMC 2014 30 EG Elektromagnetische Vertr glichkeit EMV Die Richtlinie Emissionen EN 55032 2012 Immunit t EN 55024 2010 A1 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 Sicherheit 2006 95 EG Niederspannun...

Страница 22: ...ompatibilit elettromagnetica EMC Emissioni EN 55032 2012 immunit EN 55024 2010 EN 301 489 1 v1 9 2 2011 09 EN 301 489 17 V2 2 1 2012 09 EN 61000 3 2 2006 A1 2009 A2 2009 e EN 61000 3 3 2008 Sicurezza...

Страница 23: ...de compatibilidad electromagn tica EMC Emisiones EN 55032 2012 inmunidad EN 55024 2010 EN 301 489 1 v1 9 2 2011 09 EN 301 489 17 V2 2 1 2012 09 EN 61000 3 2 2006 A1 2009 A2 2009 e EN 61000 3 3 2008 S...

Страница 24: ...idade Electromagn tica EMC Emiss es EN 55032 2012 Imunidade EN 55024 2010 EN 301 489 1 v1 9 2 2011 09 EN 301 489 17 V2 2 1 2012 09 EN 61000 3 2 2006 A1 2009 A2 2009 e EN 61000 3 3 2008 Seguran a 2006...

Страница 25: ...Electrical and Electronic Equipment WEEE directive 2012 19 EC The WEEE directive requires the manufacturers of electrical and electronic equipment who sell in EU countries 1 label their equipment to n...

Отзывы: