8
Terminal data
8.1
Encoder inputs
Ab, Fd, and Fr encoders
1
Channel A, Frequency or Forward inputs
2
Channel A\, Frequency\ or Forward\ inputs
3
Channel B, Direction or Reverse inputs
4
Channel B\, Direction\ or Reverse\ inputs
5
Marker pulse channel Z
6
Marker pulse channel Z\
Type
EIA 485 differential receivers
Maximum frequency
600kHz
Line loading
<2 unit loads (for terminals 1 to 4)
32 unit loads (for terminals 5 and 6)
Line termination components
120
Ω
Working common mode range
+12Vdc to –7Vdc
Absolute maximum applied voltage relative to
0V
±
25V
Absolute maximum applied differential voltage
±
25V
7
0V Common
8
External power supply decoupling
Maximum voltage
±
50Vdc