SM-Encoder Plus User Guide
11
Issue Number: 3
www.controltechniques.com
Figure 4-2 Fitting the SM-Encoder Plus
7. Re-fit the terminal cover to the drive
.
(For removal / re-fitting instructions, see
Unidrive SP Solutions Module Installation Sheet
provided with the Solutions
Module
.
)
8. Connect the AC supply to the drive.
9. Set Pr
0.49
to L2
to unlock read only security.
10. Check that Menu 15 (slot 1), 16 (slot 2), or 17 (slot 3) parameters are now available.
11. Check that Pr
15.01
, Pr
16.01
or Pr
17.01
shows the correct code for the SM-
Encoder Plus (code = 104).
12. If the checks in steps 10 and 11 fail, either the SM-Encoder Plus is not fully inserted,
or the Solutions Module is faulty.
13. If a trip code is now present refer to Chapter 7
Diagnostics