ATTENTION!
Always close cabinet and dust collector doors before blasting. All doors
must be kept closed during blasting. Always wear blast gloves. Never point
the blast nozzle toward the view window.
Use the blow-off nozzle to blow media off parts before opening doors.
Keep doors closed after blasting and the exhauster on until the cabinet is
clear of all airborne dust.
If dust leaks are detected, stop blasting immediately.
- ECO-80P/100P/120P/140P
- 20kg
- ECO-80PF/100PF/120PF/140PF
- 20kg
- ECO-80PL/100PL/120PL/140PL
- 20kg
4.2.2 Unloading Media
To empty media out of the blast cabinet, pressure must first be reduced to 3bar. Then
place an empty container on the grate of the cabinet. Remove nozzle and washer from
nozzle holder, close the door and choke valve, and depress the foot pedal. Media flow is to
be directed into the container until full. Repeat as often as necessary until the machine is
empty. Whilst handling the container, local Operational Health and Safety regulations are to
be observed. When the machine is empty, return the choke valve to the fully open position.
Inspect and clean the threads on nozzle holder and nozzle before reinstalling nozzle washer
and nozzle.
4.2.3 Loading and Unloading Parts
Parts may be loaded and unloaded through the front cabinet door. The door may be
opened so far as to allow loading from above, allowing use of a travelling crane, thereby
increasing operator safety. Blasted parts must be free of oil, water, grease, or other
contaminants that will clog media or filters. By closing the door, be certain that the door is
sealed securely or door interlock system will prevent blasting.
4.2.4 Blasting Operation