CONTRACOR
®
ECO-series pressure blast cabinets
21
ATTENTION!
Never look into the reclaimer exhauster outlet while the exhauster is
turning. Serious injury to the eyes or face can occur from objects being
ejected from the exhauster.
4.1.4 Electrical Power Connection
A wiring plan is provided with the cabinet. Check the motor rotation after wiring is
finished by momentarily turning the switch on and off. The motor will turn slowly. Inspect
the rotation of the motor fan through the slots in the motor's housing. The fan should rotate
clockwise when observed from the end of the fan towards the motor.
ATTENTION!
A qualified electrician must carry out all electrical work according to the
national and local standards.
4.1.5 Cabinet Static Pressure
Cabinet static pressure must be set to match the cabinet dimensions. The pressure
inside the cabin is adjusted with the throttle valve which is located on the air & dust suction
pipe on the dust collector. Try different settings of the throttle valve whilst blasting until the
cabin visibility is good when the exhausting fan is switched on.
4.1.6 Foot Pedal
For easy access, the pedal should be situated on the floor at the front of the cabinet.
The blast cabinet is intended to be operated by one-person. You must be able to remove
your foot rapidly from the pedal in an emergency.
4.2. Blasting Operation
4.2.1 Loading Media
With the exhauster off, add clean dry media, by pouring it into the cabinet hopper
through the cabinet loading door. Do not fill past the cone on the reclaimer. Overfilling will
result in media carryover to the dust collector and possibly blockage in the conveying hose.
Refill only after all media has been recovered from the cabinet. The minimum amount of
media to charge the system is as follows:
Содержание ECO-100P