ELECTRONIC CONTROL FOR REFRIGERATORS, FREEZERS AND WARMERS
OPERATIONS MANUAL
HOW TO INITIATE A MANUAL DEFROST
A one-time additional defrost may be necessary to clear accumulated ice from the evaporator coil.
1. Press and HOLD the “UP” and “DOWN” buttons
simultaneously.
2. After 5 seconds, the defrost icon will illuminate.
RELEASE the defrost buttons.
Defrost will terminate when the pre programmed temperature or time duration has been reached.
The manual defrost can also be manually terminated by pressing and holding the “Up” and “Down”
button for 5 seconds.
COMPRESSOR
EVAP FAN
DEFROST
AUX HTRS
ALARM
AUX HTRS (UP)
SET (MUTE)
POWER (DOWN)
DEFROST
2 BUTTONS