![Continental Refrigerator C0EA21K Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/continental-refrigerator/c0ea21k/c0ea21k_operation-manual_2657363011.webp)
11
easy
ELECTRONIC CONTROL FOR REFRIGERATORS, FREEZERS AND WARMERS
OPERATIONS MANUAL
HOW TO CHANGE THE HIGH AND LOW TEMPERATURE ALARM SET POINTS
The controller has a high and low alarm set point. These values can be modified per the end user
requirements. There is a pre programmed time delay for the alarm to activate to eliminate nuisance
alarms.
1. Press and HOLD the “SET” button until “PS” appears
flashing in the display. RELEASE the “SET” button.
2. Press the “UP” button
until “AL” (Low Alarm
Setting) or “AH” (High
Alarm Setting) appears
in the display. RELEASE
the “UP” button.
3. Press and RELEASE
the “SET” button. The
current alarm setting
will be shown.
4. Press the “UP” or “DOWN” to get to the new
alarm set-point. Release the button. In this case
the “UP” button was pressed until the new set point
of 55.0°F was reached.
5. Press and HOLD the
“SET” button for 5
seconds to confirm
and save the new value.
When complete, the
current temperature will
be displayed. RELEASE
the “SET” button.
COMPRESSOR
EVAP FAN
DEFROST
AUX HTRS
ALARM
AUX HTRS (UP)
SET (MUTE)
POWER (DOWN)
DEFROST
2 BUTTONS