Continental Hydraulics Installation Manual
Page 13 of 15
CEM-SD-A
CHI 1013477 May 2012
READY pin 1 digital output:
The READY digital output reports the system status.
Pin 5 will be held “high” (on) when ENABLE is connected, and there are no system errors.
Pin 5 will be pulled “low” (off) under the following conditions:
1.
When ENABLE is removed
2.
When SENS is turned on and the input is outside the 4 to 20mA range
3.
When other internal errors are present
LED function:
Green (Ready)
Steady on
System OK
Blinking
4 to 20mA current input command is out of range
Blinking
internal error sensed
Yellow (Status)
Steady on
Load is within InPOS tolerance
Off
Load is not within InPOS tolerance