W415-0893 / B / 08.01.12
28
7.2 COMBUSTION AIR CONTROL
!
WARNING
APPLIANCE OPERATION DOES REQUIRE AIR. DO NOT TAKE AIR FROM OTHER FUEL BURNING AP-
PLIANCE WHICH CAN RESULT IN IMPROPER VENTING (SMOKING) OR AIR DILUTION. ALWAYS PRO-
VIDE ADEQUATE MAKEUP AIR.
If the outside combustion air is not used, air will still be drawn directly into the appliance through the lower
louvres. Outside and inside air may be combined by pulling the outside air lever out as far as possible, and
turning the lever 90° to its locking position.
Should you fi nd a frost build up on the air control box or a draft from the appliance, close the outside air lever
when the appliance is not in use.
Air control box is shipped with inside air cover plate in open position.
5
4
3
2
1
HIGH
LOW
DRAFT
CONTROL
OUTSIDE AIR LEVER
IN CLOSED POSITION
COVER INSIDE AIR
OPENING WHEN OUTSIDE
AIR IS BEING UTILIZED.
5
4
3
2
1
HIGH
LOW
DRAFT
CONTROL
PULL OUTSIDE
AIR LEVER FULLY
OUT WHEN INSIDE
AIR COVER PLATE
IS CLOSED.
INSIDE AIR COVER
PLATE (CLOSED)
SHIPPED IN OPEN
POSITION
INSIDE AIR OPENING
(OPEN)
OUTSIDE AIR LEVER IN
OPEN POSITION
Содержание CZ-26
Страница 43: ...W415 0893 B 08 01 12 43 14 0 SERVICE HISTORY 43 1...
Страница 44: ...W415 0893 B 08 01 12 44...