W415-0893 / B / 08.01.12
14
* The fi rst fl ue offset closest to the top of the appliance must be a minimum distance of 12” from the
top of the appliance.
1.
Move the appliance into position. Try to center the exhaust fl ue of the appliance,
midpoint between two joists to prevent having to cut them. Use a plumb bob to
line up the centre.
2.
Cut and frame an opening in the ceiling to provide a
minimum clearance of 2” between the outside of the
chimney and any combustible material.
DO NOT FILL
THIS SPACE WITH ANY TYPE OF MATERIAL!
Nail
headers between the joists for extra support. Firestop
spacers must be placed on each framed opening in
any fl oor or ceiling that the chimney passes through.
3.
Hold a plumb bob from the underside of the roof
to determine where the opening in the roof should
be. Cut and frame the roof opening maintaining
proper 2” clearances.
NOTE: 30° or 45° offsets may be installed back to
back.
63.1_2B
11 FT
MINIMUM
34 FT
MAXIMUM
11 FT
MINIMUM
34 FT
MAXIMUM
11 FT
MINIMUM
34 FT
MAXIMUM
RAIN CAP
RAIN CAP
RAIN CAP
STORM COLLAR
ROOF FLASHING
STORM COLLAR
ROOF FLASHING
STORM COLLAR
ROOF FLASHING
ATTIC INSULATION
SHIELD
ATTIC INSULATION
SHIELD
ATTIC INSULATION
SHIELD
CEILING RADIATION
SHIELD
OFFSET
SUPPORT
OFFSET
SUPPORT
FIRESTOP
FIRESTOP
12” MIN*
12” MIN*
2"
Min
2"
Min
2"
Min
2"
Min
Typical Roof Joist
Framing
Typical Joist Framing
STRAIGHT CHIMNEY
SINGLE OFFSET
CHIMNEY
DOUBLE OFFSET
CHIMNEY
HEADERS
FIRESTOP SPACER -
UNDERSIDE OF JOIST
4.2 TYPICAL CHIMNEY INSTALLATION